James Gosnold wrote:
> Dave,
> 
> If I press the 'loopback' button on the DSU itself then the router
> recognises this and shows Interface up, line protocol down (looped).

   This is normal for non HDLC encapsulated circuits.  I keep two RJ45 
homemade loopback plugs in my desk, one for 56K and one for T1 to test, 
this is why I mentioned hardwire.

> 
> Strange thing I noticed is that if I chance encapsulation to HDLC and press
> the local loopback button on the DSU I get Interface up, line protocol up
> (looped).

   If you can do a loopback with a loopback jack try it or better yet 
loop from the dmarc.

  Of coarse you may have to beat up the telco some more too as they ll 
too often declare a line good after minimal and incomplete testing.
(see I'm not biased:)

   Dave

> 
> 
> MADMAN wrote:
> 
>>I have seen moe than once a faulty WIC-1DSU-T1 cause similiar 
>>problems.  Have you tried doing your own hardwire loop?
>>
>>   Dave
-- 
David Madland
CCIE# 2016
Sr. Network Engineer
Qwest Communications
612-664-3367

"Government can do something for the people only in proportion as it
can do something to the people." -- Thomas Jefferson




Message Posted at:
http://www.groupstudy.com/form/read.php?f=7&i=69603&t=69573
--------------------------------------------------
FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]