Have you tried to use a special crossover cable... that is db60 both ends but wired
with
one end dce and the other dte. To make it work you add the command clockrate 64000
(for
example) on the interface that has the dce end. If you try to add clockrate on the dte
end ..it will not allow you to do so. If you do a show controler serial (port no) it
will tell you what type of end is attached.
ps I sell these specials cables on ebay and direct.
bob...aka barronvonpuppy
Eric ding wrote:
> two 2500 routers,routerA and routerB, back-to-back connection .both of
> them use serial 0,when i set routerA's serial for dce,i got the output
> below:
> routerA(config-if)#dce-terminal-timing-enable
> %not allowed on dte interface
> but if i use the command below:
> routerA(config-if)#no dce-terminal-timing-enable
> routerA(config-if)#dce-terminal-timing-enable
> it does work.
> i was confused about it!
> any suggestion will be appreciated!
>
> _________________________________
> FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html
> Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]
_________________________________
FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]