Hi,
You are not going to see anything until the provider activates the
frame relay port that you are tied into.  

>From your description, all that has happened is that the lec came out and
install a local access circuit to your provider.

If you have configured your serial int for frame relay, it will send out a
lmi status request to the frame switch. Once your proivder activates the
frame port, it will see the request and then reply back with a lmi status. 
If they have not turned up the port, all your router will do is send out the
request but it will not get back anything, thus.. you will not see anything
new on the router.

Paul