I don't know if this is the problem, but if you have keepalives disabled
with the 'no keepalive' command, the link will stay up even though the PVC
goes down.

A 'show conf' from both routers would help.

Hth,

Ole

~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 Ole Drews Jensen
 Systems Network Manager
 CCNA, MCSE, MCP+I
 RWR Enterprises, Inc.
 [EMAIL PROTECTED]
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ 
 http://www.RouterChief.com
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 NEED A JOB ???
 http://www.oledrews.com/job
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~


-----Original Message-----
From: Jim Bond [mailto:[EMAIL PROTECTED]]
Sent: Thursday, September 20, 2001 4:56 PM
To: [EMAIL PROTECTED]
Subject: frame relay question [7:20609]


Hello,

We have AT&T frame line between US and Asia. Sometimes
frame line is not available (therefore ISDN backup
kicked in). But the weird thing is on both side frame
routers, show serial interface says up. I couldn't
ping between the 2 frame routers. Worse, on the syslog
server, the link down was not captured 'cause the
serial were still "up". 

What can I do to collect some fact and data so I can
yell at AT&T?

Thanks in advance.

Jim