Comments inline...

--- The Long and Winding Road
 wrote:
> ""Larry Letterman""  wrote in message
> [EMAIL PROTECTED]">news:[EMAIL PROTECTED]...
> > Pris,
> >
> > In our 6509's we used to make the native vlan and
> the data vlan
> > the same and it was something other than 1...if a
> blade fails and
> > we put in a new one , it defaults to vlan 1 for
> all ports. If the
> > blade has trunk ports in it, they get set to
> native vlan 1. The other
> > end is set for something else, this resulted in
> vlan mismatch in the vtp
> > domain, and in a lot of instances we suffered stp
> recalcs that took
> > buildings down for periods of time...we
> subsequently have returned to
> > making native vlan 1 on all trunks and have not
> had any issues since..
> >

I want to clarify a few items so we fully understand
this behavior so next time I need to hot-swap I am
prepared to make config changes as well. 

I thought the running config in RAM (and NVRAM) stayed
the same when swapping *same model* blades in the same
slot. If this isn't the case, then is some of the
config the same and some is defaulted?

Can you point us to a cisco doc explaining this
behavior?

Thank you very much! 



__________________________________________________
Do you Yahoo!?
Faith Hill - Exclusive Performances, Videos & More
http://faith.yahoo.com




Message Posted at:
http://www.groupstudy.com/form/read.php?f=7&i=55782&t=55743
--------------------------------------------------
FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]

Reply via email to