Comments inline... --- The Long and Winding Road wrote: > ""Larry Letterman"" wrote in message > [EMAIL PROTECTED]">news:[EMAIL PROTECTED]... > > Pris, > > > > In our 6509's we used to make the native vlan and > the data vlan > > the same and it was something other than 1...if a > blade fails and > > we put in a new one , it defaults to vlan 1 for > all ports. If the > > blade has trunk ports in it, they get set to > native vlan 1. The other > > end is set for something else, this resulted in > vlan mismatch in the vtp > > domain, and in a lot of instances we suffered stp > recalcs that took > > buildings down for periods of time...we > subsequently have returned to > > making native vlan 1 on all trunks and have not > had any issues since.. > >
I want to clarify a few items so we fully understand this behavior so next time I need to hot-swap I am prepared to make config changes as well. I thought the running config in RAM (and NVRAM) stayed the same when swapping *same model* blades in the same slot. If this isn't the case, then is some of the config the same and some is defaulted? Can you point us to a cisco doc explaining this behavior? Thank you very much! __________________________________________________ Do you Yahoo!? Faith Hill - Exclusive Performances, Videos & More http://faith.yahoo.com Message Posted at: http://www.groupstudy.com/form/read.php?f=7&i=55782&t=55743 -------------------------------------------------- FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]