I see 3 SYNC packets: One SYNC packet with 10.x.x.x from my repeater to the TRUST.
--- TRUST responds witj OK= 0 0 0 4 0 0 0 0 --- One SYNC packet from TRUST to my repeater with 10.x.x.x That is the IP update I sent before. ---- The third SYNC packet with PC-IP address and more detail. I use all three. Scott. --- In dstar_digital@yahoogroups.com, John Hays <j...@...> wrote: > > > On Jul 24, 2009, at 12:33 PM, dlake02 wrote: > > > Scott > > > > In the initial packet, the IP address is set to a 10.X.X.X/28 > > address. You won't see that in the database, because it is only sent > > until the Zone RP is authorized. > > > > Once authorized, the IP address used is the one that the Trust > > Server picks up from source IP of the poll. > > > > Also, once registered, each module registers with a 10.X.X.X/28 > > address so that DD traffic can reach it. > > > > David > >