You could also try moving the GFCI to the panel box by installing a GFCI breaker in the panel box and replacing the GFCI outlet with a normal one. This might solve the problem by increasing the distance between the RFI source and the breaker. Also the shielding provided by the panel box may help.
Of course this assumes you do not have anything on the circuit which you would not want GFCI for (like lights, smoke detectors etc.) Lou W2ROW John Shadle wrote > > Hi all, > I realize that this is tangentially related to Elecraft gear since I'm > using a K3 and experiencing this issue, but I thought someone else may > have some knowledge to share with me to help me solve my problem. > > Recently I stopped using a 25' long extension cord to power my > computer, power supply, and other accessories and installed a 2 gang > box directly off of the main electrical panel, where my shack happens > to be (in the basement). While our basement is waterproofed, it still > has a concrete floor, which "requires" a GFI outlet (according to my > electrician). To do my due diligence, I installed one GFI in the 2 > gang box and 1 regular 3-prong grounded outlet. I have my shack > computer, my power supply, and my transformer for my SGC SG-231 > autotuner plugged into this. > > Last night I tuned up (15W) 20m and was hoping to work some DX. My SWR > showed <2.0:1 on my SWR meter and on the K3. All is good. When I keyed > down with 100W, the GFI tripped and my shack computer, power supply, > etc. shut off. > > I'm using Leviton smartlockpro 20A GFCI outlets from Home Depot. > They're not "cheap", but maybe they don't have adequate RFI protection > (obviously). > > I suppose the first solution is to remove the GFI from the situation, > but I thought using it was the "right thing to do". Any personal > anecdotes or advice would be welcome. > > Thanks! > -john W4PAH > Madison, WI > ______________________________________________________________ > Elecraft mailing list > Home: http://mailman.qth.net/mailman/listinfo/elecraft > Help: http://mailman.qth.net/mmfaq.htm > Post: mailto:Elecraft@.qth > > This list hosted by: http://www.qsl.net > Please help support this email list: http://www.qsl.net/donate.html > -- View this message in context: http://elecraft.365791.n2.nabble.com/K3-GFI-outlet-100W-on-20m-and-poof-RFI-tp7559926p7559932.html Sent from the Elecraft mailing list archive at Nabble.com. ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:Elecraft@mailman.qth.net This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html