Jeremy,

What range is your external wattmeter set for? If it is 100 watts or 200 watts, you will probably not get any deflection at 2.4 watts.

When the load is 50+j0 ohms, you can rely on the K2 display.
I suggest removing the external wattmeter and using the display.

73,
Don W3FPR

On 3/6/2013 3:55 PM, JeremyJones wrote:
Looks like a bad coax was indeed causing the high current issue.  I've
resolved that, but I'm still show no power out on the external watt meter,
while the internal is reading 2.4.

Jeremy
VA3ZTF


______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html

Reply via email to