Kirk Wallace wrote:
> On Tue, 2010-12-21 at 06:21 -0700, Jonathan George wrote:
>   
>>         
>> Ok, so my whole point was that in my opinion the best device for
>> digitizing a thermocouples milli-volt signal is the MAX6675 IC. This
>> device is great because all you have to do is hook the thermocouple up
>> to it and read the temperature using some SPI interface. I have used
>> these devices with an Arduino (read cheap and easy IO) with EMC and
>> other software. You can read several of these devices using an arduino
>> and I think it is the cheapest way to get a thermocouple signal into a
>> PC. 
>>     
Gee, couldn't you just hook the SPI to a PC parallel port and do it all 
in software?

Jon

------------------------------------------------------------------------------