--- John Kasunich <[EMAIL PROTECTED]> wrote:
> Stephen Wille Padnos wrote:
>
> >> # connect index pulses to motion controller
> >> # do these when index pulsing is figured out
> >> net Xindex axis.0.index-enable ppmc.0.encoder.00.index-enable
> >> net Xindex axis.1.index-enable ppmc.0.encoder.01.index-enable
> >> net Xindex axis.2.index-enable ppmc.0.encoder.02.index-enable
> >>
> >>
> > It would probably be helpful to name these Xindex, Yindex, and
> Zindex ...
>
> Yep.
>
> The above lines create a single signal Xindex, which is connected
> to all three motion controller axes, and all three encoders. So
> when ANY axis gets an index pulse, index enable is reset for ALL
> axes.
>
> When you connect things in peculiar ways, you get peculiar
> results.
>
Shouldn't this cause an error?!
> Regards,
>
> John Kasunich
>