Chris make sure you are up to version 2.2.2
There are some bugs in the wizard regarding home/limit switch setup.

You may find it easier to just rewire the switches.

The "most simple" configuration is to put all the homes on one pin and
all the limits on another pin.  Have a pull up resistor on each pin and any 
on of the switches can pull
the line to ground.



----- Original Message ----- 
From: "Chris Barker" <[EMAIL PROTECTED]>

> Good Evening,
>
> I am working through the setup of my router table using the Stepconf 
> Wizard.
> I have a question about how to configure my home and limit switches in
> the wizard.
> My machine is already setup and running using Turbocnc.
> The way I already have my limits setup is:
>
> Each axis has it's own home switch. The home switch also acts as a
> minimum limit when home isn't being used.
> 3 input pins are used. Active low.
>
> Maximum travel limits are combined on all axes in a serial conection.
> Active low.
> Only 1 pin is used on the par. port.


-------------------------------------------------------------------------