Ok, what I had been running was 4x60uf caps between 1 and 3 and 1x60uf cap between 2 and 3 (generated leg on 3 then) and that seemed to work the best.
at the phase converter to ground 1 = 120v, 2 = 120v, 3 = 226v phase to phase 1 + 2 = 244v, 2 + 3 = 248v, 1 + 3 = 262v at the 380v taps on the transformer to ground 1 = 205v, 2 = 205v, 3 = 324v phase to phase 1 + 2 = 388v, 2 + 3 = 394v, 1 + 3 = On 5/9/2012 7:59 AM, andy pugh wrote: > On 9 May 2012 13:51, John Thornton<bjt...@gmail.com> wrote: >> I don't understand what you mean by "weak" leg? > You said you had it "wildly out of balance" ? > ------------------------------------------------------------------------------ Live Security Virtual Conference Exclusive live event will cover all the ways today's security and threat landscape has changed and how IT managers can respond. Discussions will include endpoint security, mobile security and the latest in malware threats. http://www.accelacomm.com/jaw/sfrnl04242012/114/50122263/ _______________________________________________ Emc-users mailing list Emc-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/emc-users