On 05/03/2014 02:51 AM, Frederic RIBLE wrote:
>
> I would like to clarify an important fact: the picture from the wiki is
> taken with a workpiece / camera distance of 100mm.
> At this distance, I achieved better than 0.05 mm accuracy, but with
> uncomfortable conditions.
> I agree, 0.1mm is the practical performance figure at this distance with
> this setup.
> Better resolution can be reach when going down to 25 mm distance as
> demonstrated here
> http://blog.f1oat.org/2014/05/03/hd5000-edge-finder-test-at-25-mm-distance/
OK, I didn't know how close this unit would focus.  I think 
I am going
to try with a unit specifically marketed as a MICROSCOPE rather
than a camera.  (I was confused as some of these cameras are
listed with 200X in the title line, which makes one think they
are microscopes, but the 60 degree field of view does not sound
like a microscope.)

Thanks for the info!

Jon

------------------------------------------------------------------------------