On 29 October 2014 20:48,  <p...@wpnet.us> wrote:
> Ok, I added a separate field 5V supply with common ground with the field 24V 
> supply. I also fixed a bad connection on the MPG A channel and the count 
> value does indeed go up and down with the MPG wheel. What I still don't have 
> is any axis movement (keyboard jog works fine). :(

For jogging to happen:
1) the encoder counts value needs to be connected to the axis.N.jog-counts
2) the axis.N.jog-enable pin needs to be TRUE (either setp or net)
3 the axis.N.jog-scale value needs to be non-zero (either net or setp)


-- 
atp
If you can't fix it, you don't own it.
http://www.ifixit.com/Manifesto

------------------------------------------------------------------------------