On Sun, 5 Apr 2020 at 09:40, andrew beck <[email protected]> wrote:

> So I have a 5i25 and 7i76 currently connected I'm running out of io, so am
> thinking of getting a 7i73 for the console buttons eg cycle start so that I
> can free up my 7i76 io for the toolchanger.

A 7i73 hanging on the 7i76 smart serial port is a good solution from
the point of view of simplifying wiring if nothing else.
I have one inside the apron of my lathe, to handle the MPGs and limit
switches. It's a bit under-utilised in that role, but does make for a
lot fewer wires running through the cable chain.

But, don't forget that the 5i25 has a second 25-pin port for another
7i76 or any number of other options. (up to and including a 7i74 and 8
more smart-serial cards)

-- 
atp
"A motorcycle is a bicycle with a pandemonium attachment and is
designed for the especial use of mechanical geniuses, daredevils and
lunatics."
— George Fitch, Atlanta Constitution Newspaper, 1912