Hi Vaughn, I didn't think you had to do anything special. When I have multiple sheets I just use the same net name for signals that are the same (ie connected together). gnetlist sorts it out when you give it multiple pages.
Peter. On Wed, 2006-09-27 at 06:36 -0700, Vaughn Treude wrote: > Hello everyone: > Sorry, but I'm having a little trouble figuring this one out. > My circuit diagram is on two sheets. I need to connect a small number > of signals between them. I found the symbols input-1 and output-1 which > looked just like the ones that people use for this purpose. I added > them to the circuit and designated them IO1 through IO6. One one board, > IO1 through IO3 were inputs and IO4 through IO6 were outputs, on the > other, vice versa. Of course the net list does not generate correctly; > I have to edit it by hand to merge the twelve nets with IO designators > in them. Also I ended up defining slots, since gschem didn't like the > duplicate designators. So now the program complains about incomplete > slot definitions. I'm sure there's something I'm missing. Is there a > special property or something I can define for these symbols so this > works correctly? Thanks! > Vaughn T > > > > > _______________________________________________ > geda-user mailing list > geda-user@moria.seul.org > http://www.seul.org/cgi-bin/mailman/listinfo/geda-user _______________________________________________ geda-user mailing list geda-user@moria.seul.org http://www.seul.org/cgi-bin/mailman/listinfo/geda-user