Hi Chip, Ron, and Steve:

    This here is the script that works on windows 7 as stated at the bottom 
of the email. I still have to ask, why is it that this works as is, and it 
is not a semi sync but an async call and does work in Windows7 but not 
inside the WE ConnectEvent?
As I stated in my reply to Chip, when taking out the on error the call back 
error is no parameters, not correct amount if I removed them but no error if 
I place them back in, meaning the sub routine parms when using the WE 
ConnectEvent.
    But, and I do mean But, there is never a call to that subroutine in the 
ConnectEvent, but there is one when inside a script outside of the WE 
Scripting model. No errors, just no call to it, for I removed any error 
trapping and no errors happen.
This  registry change does work as a .vbs file outside of WE in Windows 7:
 'Make this file inside windows 7 as RegistryChange.vbs
' then go to the registry path specified here and change a file name and 
watch the msgbox come up.
' after exiting the msgbox
' then change the name back and watch the msgbox come up again.
 Set wmiServices = GetObject("winmgmts:root/default")
 Set wmiSink = WScript.CreateObject( _
       "WbemScripting.SWbemSink", "SINK_") Dim strWMIKeyPath:
 strWMIKeyPath =
 "KeyPath='SOFTWARE\\Microsoft\\Windows\\CurrentVersion\\Uninstall'"
 wmiServices.ExecNotificationQueryAsync wmiSink, _ "SELECT * FROM
 RegistryKeyChangeEvent " _
 &   "WHERE Hive='HKEY_LOCAL_MACHINE' AND " _
 &   strWMIKeyPath
 WScript.Echo "Listening for Registry Key" _
       &   " Change Events..."&   vbCrLf
 While(True)
       WScript.Sleep 1000
 Wend
 Sub SINK_OnObjectReady(wmiObject, wmiAsyncContext)
       WScript.Echo "Received Registry Change Event" _
           &   vbCrLf&   wmiObject.GetObjectText_()
 End Sub


Sent: Friday, April 06, 2012 9:43 PM
Subject: Re: ConnectEvent and ConnectObject Issue?


Hi Chip,

    I thought I had read that once before and had saved so many things, I
got lost at where I had read it. I had gone through al 3 of them and never
went back to the semi sync event.

    I spent tonight verifying the call back and that works. I removed my
error trap which went right on by with the resume next, once I removed that
I got back to errors to reduce down to one thing s missing, that thing below
you mention.

    In other words the call back does say in the error the number of
function arguments are missing when I take them out as a test, as it should
be to insure all call back variables are correct. So the ConnectEvent is
working correctly.

    I will go back through my saved blueprints and get that one out again. I
may have tried it before but when learning and narrowing them down, I never
went back to them; probably due to XP working and never fussing as stated
below.

    So, will try it then we shall see if it works.

    Thanks Chip for jogging my memory on this one.

        Bruce

Sent: Friday, April 06, 2012 8:20 PM
Subject: RE: ConnectEvent and ConnectObject Issue?


Hi Ron,

At the site:
http://msdn.microsoft.com/en-us/library/windows/desktop/aa390420(v=vs.85).as
px

MS says:

"The following script example shows asynchronous event notification, making
use of
the SWbemServices.ExecNotificationQueryAsync
 method and SWbemSink  object.
Note
  Because the callback to the sink might not be returned at the same
authentication
level as the client requires, it is recommended that you use semisynchronous
instead
of asynchronous communication."


Could this be the issue Bruce is seeing (that WE could be expecting a
different level of authentication in it's call-backs (under Win7) than
wScript host is expecting)?

Bruce,

This site has a suggestion that you change your method of interfacing with
WMI to "semi-synchronous" (explained via linked pages from this site) to
avoid this issue.

hth,

Chip



> -----Original Message-----
> From: Ron Parker [mailto:[email protected]]
> Sent: Friday, April 06, 2012 5:09 PM
> To: [email protected]
> Subject: Re: ConnectEvent and ConnectObject Issue?
>
>
> If an expert exists on this, I'm it, and I don't see any way
> that the "format or limitations of the connectevent" could be
> at fault.
>
> If, as you say, it works on Windows XP but not on Windows 7,
> then that alone points to some cause outside of Window-Eyes,
> don't you think?
>
> How are you running your wscript script? That is, are you
> using wscript or cscript, and are you running it from
> Explorer, from a command prompt, or in some other way.
>
> Addressing the comments in your script: ConnectEvent "knows"
> that that event has two parameters. You should find that if
> you don't specify both parameters you get an error when you
> try to connect the event; do you?
>
> On 4/6/2012 4:45 PM, BT wrote:
> > Hi Steve,
> >
> >      As I noted inside the email that the WMI does work as
> long as I
> > am outside of the WE scripting environment. The WScript at
> the bottom
> > works for both XP and Windows 7 but, the one inside my app
> only works for XP.
> >      So in saying that the only conclusion is the format or
> > limitations of the connectevent. I had mentioned as a comment that
> > maybe the passed in parms are not being passed in. It would
> seem that
> > at least one should be but I am only guessing.
> >
> >      I did try the connecteventwithparameters but which one
> and how.
> > For I thought that any WMI event would automatically be
> passed in, but
> > maybe that is the issue.
> >
> >      But, it works as is on an XP machine and not the Windows 7 and
> > the WScript outside of the WE Object Model both work all the time.
> >
> >      I am at a loss and it seems to hinge on how the
> connectevent is
> > taking and passing events here.
> >
> >      So I am asking the experts on this, for it would seem they
> > someone has come across this.
> >
> >          Bruce
> >
> > Sent: Friday, April 06, 2012 3:47 PM
> > Subject: Re: ConnectEvent and ConnectObject Issue?
> >
> >
> > Bruce,
> >
> > I'm not a WMI expert by any stretch, but I am thinking that
> the added
> > security settings in Windows Vista and above may be preventing your
> > script from working as it did in XP. Do you notice any
> difference if
> > you disable the UAC?
> >
> > Regards,
> > Steve
> >
> >
> >
> >
> >
> > On 4/6/2012 3:37 PM, BT wrote:
> >> Hi Steve,
> >>
> >>       All you scriptors below is an issue I have asked several on.
> >> The one that resides inside my Unintall app works on an XP
> but not on a Windows 7.
> >>       In fact both work on the XP machine, only the one
> inside my app
> >> does not work on Windows 7.
> >>       The .vbs file at the bottom works on the Windows 7
> and alerts
> >> each time there is a change no matter the folder inside the
> >> LocalMachine hive of the registry.
> >>
> >>       So the qeustion to ask is your connect  object and event
> >> routines suppose to be the substitute for the standard
> script CreateObject ?
> >>           Sincerely
> >>           Bruce
> >>
> >>
> >>       The first one is inside my Uninstall app around line 323 and
> >> does not work in Windows 7, below that is the script and
> does work in
> >> Windows 7 when run outside of any WE app, using WScript.
> >>
> >> In Uninstall app around line 323:
> >> Dim strComputer: strComputer = "."
> >> Dim strWMIKeyPath: strWMIKeyPath =
> >> "KeyPath='SOFTWARE\\Microsoft\\Windows\\CurrentVersion\\Uninstall'"
> >> ' Universal way for all OS systems for local machine:
> >> 'Set wmiServices = GetObject("winmgmts:" _
> >> '&   "{impersonationLevel=impersonate}!\\"&   strComputer&
>   "\root\default")
> >>
> >>    Set wmiServices = GetObject("winmgmts:root/default")
> >> ' Below is one script create but inside we apps you have
> to split it
> >> into
> >> 2
> >> parts and is not working on windows 7, but does on XP:
> >> Set wmiSink = CreateObject( "WbemScripting.SWbemSink")
> >> wmiSinkConnection = ConnectEvent( wmiSink, "OnObjectReady",
> >> "Sink_OnObjectReady")
> >> wmiServices.ExecNotificationQueryAsync wmiSink, _ "SELECT * FROM
> >> RegistryKeyChangeEvent " _
> >> &   "WHERE Hive='HKEY_LOCAL_MACHINE' AND " _
> >> &   strWMIKeyPath
> >>
> >> Sub Sink_OnObjectReady( wmiObject, wmiAsyncContext) ' It could be
> >> failing because of the 2 parms needed.
> >>      msgBox " A registry change has happened! "
> >> End Sub
> >>
> >>
> >> Below is a standard script that works and reports the
> registry change:
> >> 'RegistryChange.vbs
> >> Set wmiServices = GetObject("winmgmts:root/default")
> >> Set wmiSink = WScript.CreateObject( _
> >>       "WbemScripting.SWbemSink", "SINK_") Dim strWMIKeyPath:
> >> strWMIKeyPath =
> >> "KeyPath='SOFTWARE\\Microsoft\\Windows\\CurrentVersion\\Uninstall'"
> >> wmiServices.ExecNotificationQueryAsync wmiSink, _ "SELECT * FROM
> >> RegistryKeyChangeEvent " _
> >> &   "WHERE Hive='HKEY_LOCAL_MACHINE' AND " _
> >> &   strWMIKeyPath
> >> WScript.Echo "Listening for Registry Key" _
> >>       &   " Change Events..."&   vbCrLf
> >> While(True)
> >>       WScript.Sleep 1000
> >> Wend
> >> Sub SINK_OnObjectReady(wmiObject, wmiAsyncContext)
> >>       WScript.Echo "Received Registry Change Event" _
> >>           &   vbCrLf&   wmiObject.GetObjectText_()
> >> End Sub
>