Clark,

The EXCP*BLKSIZE=MB is not true for all access methods. I'd only assume this
is correct for SAM-E, which is probably the majority of tape IO.

Ron 

> -----Original Message-----
> From: IBM Mainframe Discussion List [mailto:ibm-m...@bama.ua.edu] On
Behalf Of
> Clark Morris
> Sent: Thursday, September 23, 2010 6:03 PM
> To: IBM-MAIN@bama.ua.edu
> Subject: Re: [IBM-MAIN] Reports for GB per hour to tape
> 
> On 23 Sep 2010 07:29:51 -0700, in bit.listserv.ibm-main you wrote:
> 
> >Hi John,
> >
> >  Yes, I had thought of extrapolating channel busy % but I'm not sure
that
> would be precise enough.
> >Thanks for the suggestion.
> 
> As I recall the SMF 14 (sequential read) and 15 (sequential write)
> records have the device type and probably the address.  EXCPs times
> blocksize should give a decent approximation and taking all of the
> records for a given 24 hour period should give a fair idea of the
> number of bytes per day.
> 
> Clark Morris
> >
> >Thank You,
> >Dave O'Brien
> >NIH Contractor
> >________________________________________
> >From: McKown, John [john.mck...@healthmarkets.com]
> >Sent: Thursday, September 23, 2010 10:25 AM
> >To: IBM-MAIN@bama.ua.edu
> >Subject: Re: Reports for GB per hour to tape
> >
> >> -----Original Message-----
> >> From: IBM Mainframe Discussion List
> >> [mailto:ibm-m...@bama.ua.edu] On Behalf Of O'Brien, David W.
> >> (NIH/CIT) [C]
> >> Sent: Thursday, September 23, 2010 9:21 AM
> >> To: IBM-MAIN@bama.ua.edu
> >> Subject: Re: Reports for GB per hour to tape
> >>
> >> Hi Rex,
> >>
> >> Thanks for responding. No, we have TMS (CA-1) as our tape
> >> management system.
> >> Guess I had a senior moment earlier. The number of bytes
> >> written or read would obviously only be available at the end
> >> of the job. GB/hour is just not available for any job running
> >> past :59 of any hour. Management is not looking for GB/hour
> >> of a particular job but rather the entire workload.
> >>
> >> Guess we'll just have to test a s/w encryption product to find out.
> >>
> >> Thank You,
> >> Dave O'Brien
> >> NIH Contractor
> >
> >Are your tapes on dedicated channels? What about an RMF channel (or
device)
> utilization report? Just guessing!
> 
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO
> Search the archives at http://bama.ua.edu/archives/ibm-main.html

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to