On Apr 9, 2006, at 9:30 PM, Paul Gilmartin wrote

---------------------------SNIP---------------------
    //STEP     EXEC PGM=IKJEFT01,DYNAMNBR=whatever
    //SYSTSPRT  DD  SYSOUT=(,)
    //SYSTSIN   DD  *
       copy old.file new.file

Agreed, a sight improvement.  But I tried it and got:

 CSV003I REQUESTED MODULE COPY     NOT FOUND
 CSV028I ABEND806-04  JOBNAME=SPPG      STEPNAME=$STCTSO1
 IEA995I SYMPTOM DUMP OUTPUT
 SYSTEM COMPLETION CODE=806  REASON CODE=00000004
  TIME=20.23.10  SEQ=00116  CPU=0000  ASID=0057
  PSW AT TIME OF ERROR  070C1000   812A19AE  ILC 2  INTC 0D
    NO ACTIVE MODULE FOUND
    NAME=UNKNOWN
    DATA AT PSW  012A19A8 - 9024181E  0A0D18FB  180C181D
    GR 0: 00001E00   1: 84806000
       2: 00FCBC10   3: 00000000
       4: 00000000   5: 006B9550
       6: 000000FF   7: 00000000
       8: 006A5250   9: 012A1E74
       A: 00000000   B: 00000004
       C: 00000000   D: 006A5250
       E: 84806000   F: 00000004
  END OF SYMPTOM DUMP
 Command 'COPY    ' abended with code 806000. Load module not found.
 ISPD210  CMD abended - 'COPY' terminated abnormally.
 ***

And:
----------------SNIP------------

You didn't purchase the extra cost TSO Utilities (see my earlier post to Ted.

Ed

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html