Just curious - I thought that only Serverpac required the use of z/OSMF and CBPDOs are installed using traditional methods. Are there now products which have to be installed using z/OSMF ? Is it now possible to install a CNPDO using z/OSMF.
For the record my experience of z/OSMF for Serverpac installation has been positive - I would not want to go back to the ISPF dialogue method. Keith Gooding > On 30 Aug 2022, at 13:37, Carmen Vitullo <petevi...@gmail.com> wrote: > > I don't recall ever having to work or needing to use a product to install or > maintain a product that required another product as finicky as z/osmf > > at my 2.4 level downloading a product to support that level, the json file > version was not compatible.... WTH, > > opening a case with IBM apparently there's an APAR PTF, sorry this is just > insane using a product built on Java to support a Mainframe product and have > this much incompatibility :( > > sad, very sad > > MHO > > Carmen > >> On 8/29/2022 8:34 PM, Robert Garrett wrote: >> zOSMF. A reasonably good idea that has been extremely poorly and sloppily >> implemented. >> >> -----Original Message----- >> From: IBM Mainframe Discussion List <IBM-MAIN@LISTSERV.UA.EDU> On Behalf Of >> Carmen Vitullo >> Sent: Monday, August 29, 2022 1:13 PM >> To: IBM-MAIN@LISTSERV.UA.EDU >> Subject: z/OSMF - again, next issue >> >> I'm working with a teammate that is required to use z/osmf to download an >> new zsecure release, we successfully added the portable software instance >> and provide the https server and client parms, updated the JOBCARD, the next >> parts we hunt and peck and guess what to do next, we found quite by accident >> we had to 'complete add' to get to the part to submit the job to download >> the product from IBM, selecting action/submit the job we get this error >> >> The request could not be completed because an error occurred. Error: >> >> IZUD999E >> >> Aug 29, 2022, 1:02:08 PM >> >> An error occurred when attempting to contact the application server. The >> server returned HTTP status code: 500. >> >> IZUG857E >> >> the IZU messages are no help, we checked the configuration for the system(s) >> and found nothing configured wrong we saw, the PDS where the JCL was stored >> we submitted via TSO /ISPF successfully, next we went on and selected NEXT >> to move to the next job/process then we got this error An error occurred >> when attempting to contact the application server. The server returned HTTP >> status code: 500. >> >> IZUG857E >> >> Aug 29, 2022, 1:02:45 PM >> I did not see any error in the IZUSVR1 address space or in the syslog. >> my question, has anyone been successful submitting from z/osmf? is there >> somewhere I can check that needs configuring I may have missed? >> thanks >> >> Carmen >> >> ---------------------------------------------------------------------- >> For IBM-MAIN subscribe / signoff / archive access instructions, send email >> to lists...@listserv.ua.edu with the message: INFO IBM-MAIN >> >> ---------------------------------------------------------------------- >> For IBM-MAIN subscribe / signoff / archive access instructions, >> send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN > > ---------------------------------------------------------------------- > For IBM-MAIN subscribe / signoff / archive access instructions, > send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN