John Deere, in the 70s had two separate power companies provide their "non-interruptible power" for their mainframes, but the DP manager was not able to also add a diesel powered backup because the only vendor with the sufficient engine to meet their power needs used ONLY a Caterpillar diesel engine. After the fourth failure in a couple of years, the DP manager finally won approval from senior company management to install a diesel powered backup, but ONLY because it was housed in a lockee Deere-shed so no one would see there was a Yellow diesel engine inside.
Or so I was told. Barry Herbert W. "Barry" Merrill, PhD President-Programmer MXG Software Merrill Consultants 10717 Cromwell Drive Dallas, TX 75229 ba...@mxg.com http://www.mxg.com - FAQ has Most Answers ad...@mxg.com - invoices/PO/Payment supp...@mxg.com - technical tel: 214 351 1966 - expect slow reply, use email fax: 214 350 3694 - prefer email, still works -----Original Message----- From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf Of Skip Robinson Sent: Monday, June 16, 2014 1:44 PM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Re: Dataset in Two master catalog I can think of several scenarios, but how about one that we can all relate to--and I'm the electric company: a data center power failure. Sure, what are the odds of a power failure requiring an enterprise-wide IPL *and* missing your one and only IODF file? Anyone? Dr. Murphy? Anyone? . . J.O.Skip Robinson Southern California Edison Company Electric Dragon Team Paddler SHARE MVS Program Co-Manager 626-302-7535 Office 323-715-0595 Mobile jo.skip.robin...@sce.com From: "R.S." <r.skoru...@bremultibank.com.pl> To: IBM-MAIN@LISTSERV.UA.EDU, Date: 06/16/2014 11:03 AM Subject: Re: Dataset in Two master catalog Sent by: IBM Mainframe Discussion List <IBM-MAIN@LISTSERV.UA.EDU> W dniu 2014-06-16 17:54, Skip Robinson pisze: > Blessed are the pessimists, for they shall take backups. ;-) > > OTOH nothing scares me more than the prospect of depending on stand-alone > restore to IPL the enterprise. For me it's a matter of training & expertise, but ...WHY STANDALONE? We talk about single file, IODF. Very important during IPL, but quite inactive during normal system run (with exception to HCD activities including ACTIVATE processing). Can you enlight us and tell us the prospect of such failure? Regards -- Radoslaw Skorupka Lodz, Poland ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN