Thomas, here is my PROFILE TCPIP (straight out of the Failover document):
NOTRACE ALL OBEY OPERATOR TCPMNT44 MAINT ENDOBEY VSWITCH CONTROLLER ON i also have them set up on TCPMAINT's 198 - again, per the Failover doc. i assume that is so that all the configuration is kept on TCPMAINT, is that the reason? prg Phillip Gramly Systems Programmer Communications Data Group Champaign, IL The IBM z/VM Operating System <IBMVM@LISTSERV.UARK.EDU> wrote on 09/20/2007 05:53:37 AM: > My guess is that you copied your existing TCPIP profile for your > VSWITCH CONTROLLERS .. It is a case of too much information. The > profiles for the controllers is very simple. > The only entry you NEED in their profile is VSWITCH CONTROLLER ON... > > Here is what my profiles for the controllers look like. > > NOTRACE OSD > > INFORM > TCPMAINT MAINT > ENDINFORM > > ASSORTEDPARMS > PERMITTEDUSERSONLY > VMDUMP > ENDASSORTEDPARMS > > OBEY > TCPMAINT MAINT > ENDOBEY > > VSWITCH CONTROLLER ON > > A note: The way I do it is to leave the profiles on TCPMAINT's 198 disk > and name them VSWCTRL1 TCPIP and VSWCTRL2 TCPIP. >