On Thursday, 06/09/2011 at 10:06 EDT, Berry van Sleeuwen 
<berry.vansleeu...@xs4all.nl> wrote:

> What can cause the CP monitor to have these duplicate records?

A type 0x05 record is, I think, produced for each LCB (Link Control Block) 
in the stack.  Does the OSA device have multiple LINKs? 

Alan Altmark

z/VM and Linux on System z Consultant
IBM System Lab Services and Training 
ibm.com/systems/services/labservices 
office: 607.429.3323
mobile; 607.321.7556
alan_altm...@us.ibm.com
IBM Endicott