is hardware RAID recovery largely superior to software raid?
i.e. a recovery from a bad disk in a raid1 configuration means an
automatic switch to the good disk and the removal of the bad disk from the
array, until a new disk is re-inserted, and at that time, hardware raid
taking steps to re-mirror the drives accordingly?

-Tony
.-._.-._.-._.-._.-._.-._.-._.-._.-._.-._.-._.-._.-._.-._.-._.-._.-._.-.
Anthony J. Biacco                       Network Administrator/Engineer
[EMAIL PROTECTED]                    Intergrafix Internet Services

    "Dream as if you'll live forever, live as if you'll die today"
http://cygnus.ncohafmuta.com                http://www.intergrafix.net
.-._.-._.-._.-._.-._.-._.-._.-._.-._.-._.-._.-._.-._.-._.-._.-._.-._.-.

On Mon, 25 Oct 1999, Brian D. Haymore wrote:

> Matthew Clark wrote:
> > 
> > Is there much info available on setting up Hardware RAID?  Most info seems
> > to be on Software (obvious reasons).. However - as you probably noticed, I'm
> > having problems with my Hardware RAID and need to sort it ASAP..
> > 
> > I was thinking about moving to kernel 2.2.13 but the parts of the kernel
> > that may have an effect on MegaRAID Hardware performance (i.e. pci.*,
> > megaraid.*, sym3c98xx.* etc) havn't been updated...
> > 
> > Regards,
> > 
> > Matthew Clark.
> > --
> > NetDespatch Ltd - The Internet Call Centre.
> > http://www.netdespatch.com
> 
> 
> I initailly purchased an AMI MegaRAID four or so months ago and saw
> horible performance.  I tried a DPT at that time as well before
> setteling on a Mylex eXtremeRAID card.  The AMI and DPT seem to both be
> hindered by what I can only speculate as to slow of a sub processor,
> their i960s.  The Mylex uses a 233Mhz StrongARM processor.  I see
> numbers that are more in harmony with software raid with this card where
> with the other two I saw performance that was more like a slow 5400 rpm
> ide drive with little cache.  As far as my tests showed, if you need
> performance, software is the way to go.  If you need the reliability of
> hardware raid, then the Mylex card was the way to go.
> 
> 
> I have numbers for all my tests that I could dig up if wanted.
> --
> Brian D. Haymore
> University of Utah
> Center for High Performance Computing
> 155 South 1452 East RM 405
> Salt Lake City, Ut 84112-0190
> 
> Email: [EMAIL PROTECTED] - Phone: (801) 585-1755 - Fax: (801) 585-5366
> 