Thanks Ron,

Would you recommend doing this for all tubes or only the ones that
show a problem? I just wonder if perhaps it would be good to do this
procedure anyways, then I can make a test circuit using some triacs.

Michel



On Dec 10, 2:56 am, glasslinger <rons...@att.net> wrote:
> Hello!
>
> Try lighting them up using AC for an hour or two. A small sign transformer
> with a variac works fine. This will fire the segments that don't light up
> using DC, and will bake off the mercury products that cause the poisoning.
> Do not run so much current through the segment that it turns red hot
> though. A few milliamps is enough.
>
> ron

-- 
You received this message because you are subscribed to the Google Groups 
"neonixie-l" group.
To post to this group, send an email to neonixie-l@googlegroups.com.
To unsubscribe from this group, send email to 
neonixie-l+unsubscr...@googlegroups.com.
For more options, visit https://groups.google.com/groups/opt_out.


Reply via email to