mps;676665 Wrote: > Sometimes the dependent library ends up empty after a rescan until I > manually refresh the library. Rescan refresh is enabled. > > The problem is intermittent and random. Is it possible that you are not > topologically sorting library dependencies, so the dependent library > gets refreshed before the libraries on which it depends? > The refresh order should be according to the "Library order" parameter value of each library, libraries with lower "Library order" value will be refreshed first and then the ones with higher number. If you have multiple dependent libraries that depends on each other, you need to set the "Library order" different to make them be refreshed in the correct order.
-- erland Erland Isaksson ('My homepage' (http://erland.isaksson.info)) (Developer of 'many plugins/applets (both free and commercial)' (http://wiki.slimdevices.com/index.php/User:Erland). If you like to encourage future presence on this forum and/or third party plugin/applet development, 'consider purchasing some plugins' (http://license.isaksson.info)) Interested in music discovery ? See 'Social Music Discovery (SMD)' (http://forums.slimdevices.com/showthread.php?p=656713) project. ------------------------------------------------------------------------ erland's Profile: http://forums.slimdevices.com/member.php?userid=3124 View this thread: http://forums.slimdevices.com/showthread.php?t=91163 _______________________________________________ plugins mailing list plugins@lists.slimdevices.com http://lists.slimdevices.com/mailman/listinfo/plugins