mps;676665 Wrote: 
> Sometimes the dependent library ends up empty after a rescan until I 
> manually refresh the library. Rescan refresh is enabled.
> 
> The problem is intermittent and random. Is it possible that you are not
> topologically sorting library dependencies, so the dependent library
> gets refreshed before the libraries on which it depends?
> 
The refresh order should be according to the "Library order" parameter
value of each library, libraries with lower "Library order" value will
be refreshed first and then the ones with higher number. If you have
multiple dependent libraries that depends on each other, you need to
set the "Library order" different to make them be refreshed in the
correct order.


-- 
erland

Erland Isaksson ('My homepage' (http://erland.isaksson.info))
(Developer of 'many plugins/applets (both free and commercial)'
(http://wiki.slimdevices.com/index.php/User:Erland). 
If you like to encourage future presence on this forum and/or third
party plugin/applet development, 'consider purchasing some plugins'
(http://license.isaksson.info))
Interested in music discovery ? See 'Social Music Discovery (SMD)'
(http://forums.slimdevices.com/showthread.php?p=656713) project.
------------------------------------------------------------------------
erland's Profile: http://forums.slimdevices.com/member.php?userid=3124
View this thread: http://forums.slimdevices.com/showthread.php?t=91163