David L. Mills wrote:
> David,
> 
> More specifically, for those survivors that show leap warnings, a 
> counter is incremented. If any survivoe, referencde clock or not, does 
> not show warning the ocunter is not incremented. For refclocks the 
> counter is set to the number of survivors, but only if the warning is 
> lit. After this, if the counter is greater than half the number of 
> survivors, the system leap warning is lit. You are welcdome to suggest 
> an alternative method on the basis that some refclocks do not implement 
> the leap warning and others may show a warning in error.
> 
> Dave

How about a leap minute every 240 years or so?