Do you want to access DHCP assigned sm using hostname instead of IP addresses ?
Have a look here.
http://community.cambiumnetworks.com/t5/PMP-450/Hostname-to-access-SM-s/m-p/48280
From: Af on behalf of Dennis Burgess
Sent: 30 November 2016 02:57:43
To: af@afmug.
FPGA Features : DES, Sched, US/ETSI;
10/03/2016 : 04:58:53 PST : :Time Set
10/03/2016 : 04:59:06 PST : Acquired sync pulse from Power Port
Chris Wright
Network Administrator
From: Af [mailto:af-boun...@afmug.com] On Behalf Of Chitrang Srivastava
Sent: Monday, October 03, 2016 11:18 AM
To: af@afmu
Hi Chris,
Please share Event logs.
Thanks,
Chitrang
From: Af on behalf of Chris Wright
Sent: 03 October 2016 23:12:01
To: af@afmug.com
Subject: [AFMUG] 450 AP Watchdog Reset
Is the watchdog reset bug still a thing? I thought it was resolved a long time
ago but
Packet of Disconnect doesn't reboot but drop the session and reconnect, that
may fix the problem that you are seeing.
Thanks,
Chitrang
From: Af on behalf of Chitrang Srivastava
Sent: 06 May 2016 20:32:23
To: af@afmug.com
Subject: Re: [AFMUG] R
If you are using RADIUS, their is a way to reboot SM without logging into AP.
We do support Packet of Disconnect from 13.4.1 onwards.
How to use is explained here:
http://community.cambiumnetworks.com/t5/PMP-Configuration-Examples/PMP-13-4-Radius-Change-of-Authorization-Feature-Brief/m-p/39955#M
@afmug.com
Subject: Re: [AFMUG] Canopy PTP230 VCERR
13.4.
On Tue, Jan 12, 2016 at 10:51 AM, Chitrang Srivastava
wrote:
> Hi Matt,
> What software version are you using?
>
> Thanks,
> Chitrang
>
> Anyone know what a VCERR on a Canopy PTP230 is?
>
>>>>Event:
Hi Matt,
What software version are you using?
Thanks,
Chitrang
From: Af on behalf of Matt
Sent: 12 January 2016 21:28:55
To: af@afmug.com
Subject: [AFMUG] Canopy PTP230 VCERR
Anyone know what a VCERR on a Canopy PTP230 is?
>>>Event: OOS, MsgType: VCERR
Hi Matt,
Please try 13.401 open beta, there is this particular issue seen with RADIUS
authentication, SM goes into registering state, Data traffic is stopped.
With 13.4.1 this is fixed.
Thanks,
Chitrang
From: Af on behalf of Matt
Sent: 21 October 2
Guys,
Please try out 13.4.1 open beta which solve this REGISTERING issue, you may
notice some debug message in Event log, they are there for investigation
purpose.
Thanks,
Chitrang
From: Af on behalf of Tushar Patel
Sent: 10 September 2015 19:02:28
To: af@af
milar logs 'logs - AP
session '
We are working on a similar issue but with RADIUS authentication for SM, for
you SM authentication is radius as well?
Thanks
Chitrang Srivastava
From: Af on behalf of George Skorup
Sent: 29 August 2015 09:30:14
To:
Hi,
For your second issue, if you are using P8 boards, it is because of NAT table
size (this will be fixed in 13.4. 1) but temporary work around is to reduce NAT
table size to 1024 on SM,
Boot up SM using default plug (NAT get disabled).
Chitrang
From: Af on
Hi Matt,
Please send engineering.cgi / cnut capture of both AP/SM(which has problems).
Thanks,
Chitrang Srivastava
Cambium Networks
From: Af on behalf of Matt
Sent: 15 August 2015 23:42:37
To: af@afmug.com
Subject: [AFMUG] Canopy 13.4 FSK Session Bug
pport case" option on the website doesn't work.
Maybe it does now, I haven't tried.
I need minions. Or maybe a Stewie Griffin cloning machine. No wait, time
machine would be better.
On 7/22/2015 10:35 PM, Chitrang Srivastava wrote:
> Hi George,
>
> Did you get a chance to ch
I read in the release notes that this was fixed. Maybe
it was in the known issues section and I'm just stupid.
On 7/17/2015 1:17 AM, Chitrang Srivastava wrote:
> Hi George,
>
> By the Freerun fix, I mean this issue, where the Power Port shows Sync but
> the Sync Status still says
Hi George,
By the Freerun fix, I mean this issue, where the Power Port shows Sync but the
Sync Status still says searching.
http://community.cambiumnetworks.com/t5/image/serverpage/image-id/279i18BB3380325BDEA1/image-size/original?v=mpbl-1&px=-1
This issue what you are reporting is still present
Hi Mark,
Yes they aren't dead, you can still use them with 13.4 release & NAT but
keeping table size to 1024.
In the next release we will fix the issue.
Thanks,
Chitrang Srivastava
Cambium Networks
From: Af on behalf of Mark Radabaugh
Sent
We will work some acceptable solution.
Because lots of new features get added in 13.4(refer Release Notes) hence the
code size get increased and we ran short of DRAM.
Thanks,
Chitrang Srivastava
Cambium Networks
From: Bill Prince
Sent: 16 July 2015 22:19
Hi Bill,
Please reduce the NAT table size from Configuration - >NAT, to 1024 and try it
out.
Thanks,
Chitrang Srivastava
Cambium Networks
From: Chitrang Srivastava
Sent: 15 July 2015 07:38:49
To: af@afmug.com
Subject: Re: [AFMUG] Software 13.4: P8
ns I guess.
On 7/13/2015 11:19 PM, Chitrang Srivastava wrote:
> Hi George,
>
> I suppose by AutoSync bug you meant Sync not coming back to power port when
> the config is Power Port+Free Run.
> If yes, then we have fixed the issue in 13.4 Official Release. Please give it
&
the above steps didn't work ( actually they should because most of our
configuration changes applies on next reboot) they please send screen shot of
NAT configuration page before you press Save Changes.
Thanks,
Chitrang Srivastava
Cambium Networks
Hi George,
I suppose by AutoSync bug you meant Sync not coming back to power port when the
config is Power Port+Free Run.
If yes, then we have fixed the issue in 13.4 Official Release. Please give it a
try.
Thanks,
Chitrang Srivastava
Cambium Networks
-Original Message-
From: Af
21 matches