All,
Hopefully someone can give me an idea on this one. Working on my own
equipment but following the labs and am running into an issue with AAR.
I'm sending a call from HQ to BR 1 using 4 digit dial 5002 --- 1002. When
I attempt to make the call I receive the message Not enough bandwidth,
config
and remove
isdn bind-l3 ccm-manager
and put it back again.
also
BR1
pri-group timeslots 1-3,24
PSTN
pri-group timeslots 1-3,23-24
should be same.
From: ccie_voice-boun...@onlinestudylist.com
[mailto:ccie_voice-boun...@onlinestudylist.com] On Behalf Of Alex Pishko
All,
Struggling with the MGCG PRI circuit in this lab. I've been through it a few
times and never had issues, however for this go around I cannot seem to get L2
up when I issue the show isdn status command. Also, when I look at the serial
inteface is shows up/up, however it's up/up
All,
Having an issue with a 7960 registering to CUCM using SIP. On the actual phone
itself keep getting the error registration rejected. Within CUCM I also see
rejected on the phone page.
I've verifed multiple times that the MAC address is correct and my SIP profile
is pretty basic as
Thanks all, it was firmware. Forgot to mention before that I had made sure
there was an extension and had checked replication as that was my inital
thought as well. Appreciate the assistance.
Alex
From: Tony Zunt tony.z...@gmail.com
To: Alex Pishko
In setting up my sessions I've noticed the it doesn't appear that when you
pre-load the configuration the proctor labs vlans match up with the vlan naming
convention as to what's in the all labs table on the ipexpert site. Such as in
all labs table hq server vlan is 30, but on preloaded config