[cctalk] Re: Diablo Model 40 Series - Disturbed head positioning

2024-05-02 Thread Curious Marc via cctalk
Yes the oscilloscope are your eyes and ears for electrons… Marc > On May 1, 2024, at 11:44 PM, Dominique Carlier wrote: > > Hi Marc ! > > It should be so great if it was just the PSU, everything else is hyper > overkill in terms of complexity but on the multimeter all the voltages show >

[cctalk] Re: Diablo Model 40 Series - Disturbed head positioning

2024-05-02 Thread Dominique Carlier via cctalk
Hi Marc ! It should be so great if it was just the PSU, everything else is hyper overkill in terms of complexity but on the multimeter all the voltages show the correct values, including +15V and -15V (generated from the +24V and -24V of the power supply). But is it possible that one of these

[cctalk] Re: Diablo Model 40 Series - Disturbed head positioning

2024-05-01 Thread Curious Marc via cctalk
Power supply problem? Marc > On Apr 30, 2024, at 8:58 AM, Dominique Carlier via cctalk > wrote: > > Hello everyone > > I need your help to identify an issue on my Diablo Model 40 Series. I don't > know where to look, it's so vast ! > > Here's the problem: > When RUN is activated, the drive

[cctalk] Re: Diablo Model 40 Series - Disturbed head positioning

2024-04-30 Thread Dominique Carlier via cctalk
I also thought about it first, but in the documentation it is clearly explained that during the startup sequence, the deployment of the heads is done at the same time as the spin up, during this deployment the heads are raised, they are normally loaded on disc only after one minute +- after

[cctalk] Re: Diablo Model 40 Series - Disturbed head positioning

2024-04-30 Thread Jon Elson via cctalk
On 4/30/24 12:37, Dominique Carlier via cctalk wrote: Thanks for your response Jon :! The technical documentation is available on Bitsavers here: http://www.bitsavers.org/pdf/diablo/disk/model_40/81603_Diablo4xMaint_Apr75.pdf But also here:

[cctalk] Re: Diablo Model 40 Series - Disturbed head positioning

2024-04-30 Thread Dominique Carlier via cctalk
Hi Don ! Good suggestion, these microswitches are used to indicate that the heads are completely retracted. Unfortunately, that would have been too simple, both microswitches work perfectly :-/ On 30/04/2024 19:43, D. Resor wrote: What is the purpose of the two microswitches seen in the

[cctalk] Re: Diablo Model 40 Series - Disturbed head positioning

2024-04-30 Thread D. Resor via cctalk
What is the purpose of the two microswitches seen in the upper right of the video view? Could one or both of those be intermittent? Have they been tested for continuity/intermittence with an analog VOM? Don Resor -Original Message- From: Dominique Carlier via cctalk Sent:

[cctalk] Re: Diablo Model 40 Series - Disturbed head positioning

2024-04-30 Thread Dominique Carlier via cctalk
Thanks for your response Jon :! The technical documentation is available on Bitsavers here: http://www.bitsavers.org/pdf/diablo/disk/model_40/81603_Diablo4xMaint_Apr75.pdf But also here: https://www.wang2200.org/docs/external/DiabloSeries40DiskDriveFieldLevelMaintenanceGuide.03-0057.pdf I

[cctalk] Re: Diablo Model 40 Series - Disturbed head positioning

2024-04-30 Thread Jon Elson via cctalk
On 4/30/24 10:46, Dominique Carlier via cctalk wrote: Hello everyone I need your help to identify an issue on my Diablo Model 40 Series. I don't know where to look, it's so vast ! Here's the problem: When RUN is activated, the drive begins its spin up and simultaneously deploys the heads