Dear Sirs,
I would like to ask you to quit sending me any more emails. I have
changed my
area of interest to something other than CNC machines now. Please do not
send
me more emails. Thanks
Farzin Kamangar
Dear EMC users,
I have a qestion about spindle brake for touchy interface. If I want to
have a button to use spindle brake and make it on or off, how can I use the
touchy.emc_interface.emc_control to turn the brake on and off? I need
something like
On Mon, Jan 23, 2012 at 6:36 PM, Chris Radek ch...@timeguy.com wrote:
On Mon, Jan 23, 2012 at 03:32:02PM +0330, Farzin Kamangar wrote:
Hello, dear EMC users,
Regarding the touchy interface, I have a problem on one computer and
that is in the MDI page with G shown as the command, when
Hello, dear EMC users,
Regarding the touchy interface, I have a problem on one computer and
that is in the MDI page with G shown as the command, when I enter 0 or 1
for G0 or G1 and with pushing the Next button I see the lines X Y Z show up
for getting their coordinates just the first time
Dear EMC users,
I was wondering how I could get the commanded positions, meaning the
commanded positions from Gcode, and show them on the GUI. In the code for
AXIS
GUI it says we could read it from emc.stat.position, but I think this is
not a correct statement. The actual positions is read
is correct. I was
looking for an interface from emc.stat which can show the correct commanded
position.
Farzin
On Sun, Jan 8, 2012 at 10:00 PM, Jon Elson el...@pico-systems.com wrote:
Farzin Kamangar wrote:
Dear EMC users,
I was wondering how I could get the commanded positions, meaning
Hello, dear EMC users;
Considering the tool changing process, is there a way to send some
movement commands from PLC to CNC?
I have entered the TOOL_CHANGE_POSITION and TOOL_CHANGE_QUILL_UP in the INI
file and in the EMCIO section. This is fine and causes the tool go to the
tool change
Hello, dear EMC users;
I checked all the manuals but I did not find anything regarding
generation of user error messages. I need to show a message when one of my
axis drives have an alarm and
cannot move the axis. I have connected one of the drive outputs to one of
parallel port inputs. When
Hello Dear EMC users,
I was looking at the mini.tcl file for the MINI GUI for EMC yesterday. I
was wondering how I could find the emc interface documentation for this GUI.
I did not see any module import for the interfaces like : emc_ini, emc_home,
emc_mode, emc_machine, emc_spindle, emc_abort,
Dear EMC users,
I have a question regarding the tool movement when angular axis A is
moving. When the angular axis A is moving, tool is not moving in the openGL
graphic page in the axis
interface. I checked the tool when angular B and angular C axes move around
Y and Z axes in the graphic page
Dear EMC users,
I have a problem when starting EMC2. I have enclosed the error-file with
this email. Sometimes I do not have this problem at all when exiting EMC and
running it again many times. But I cannot run EMC when the problem starts.
It keeps on giving the same error (non stop). I have
Dear EMC users,
Hi, I am using the TOUCHY interface and I have a problem with the length
unit. Whatever length I enter in MDI or in a program in AUTO mode is
considered in INCH. I entered G21 to make the controller consider the length
unit MM, but it does not pay attention to it. I need your
Hello EMC users,
We have a selector on our control panel with the following options for
modes of operation: AUTO - MDI - HANDWHEEL - CONTINUOUS - INCREMENTAL 1 -
INCREMENTAL 10 - INCREMENTAL 100. The four last modes are actually used in
manual mode.
I can use the halui mode for the modes
Dear EMC users,
I am going to use the Z pulse of my servo motor in order to go home with
the flag HOME_USE_INDEX = YES. Now my question is: where should I connect my
index pulse
as an input? Do I have to use a HAL encoder and set its
encoder.0.index-enable bit to YES or what. What is the
Hello EMC users,
I have difficulty when adding additional parallel ports (other than the
parallel port on mother board) and configuring them as input. When I monitor
the pins 2 to 9 they are
always off, but the pins 10 or 11 are on. I do not have this problem when I
configure the parallel port
Dear Sirs,
I want to make a PCI card for EMC. I have experience of
making ISA and PCI I/O board, but I have never done it for Linux.
Can you give me some information how can I go ahead for EMC?
Do I need to write a driver for that? Where is the interface data of EMC
Dear EMC users,
I am using a servo-motor which has a Z pulse output and I used a
software counter module and connected this signal to the phase-Z of this
module. My problem is that I am seeing
weird behaviour when I ask the axis to go home. Would you please let me know
what I need for the
Dear EMC users,
I was asked to make the following change in the controller behaviour.
As you know when we want to stop the running program and we push the stop
program button, program stops and
so does spindle from turning. Now the request is: when we stop the program
by pressing the stop
Hello EMC users,
I was wondering if I could use HAL for jog plus and jog minus for any
axis. This is like using the + and - buttons for the selected axis in the
manual page.
The idea is to use I/O through the parallel port for jog plus and jog minus.
Thanks
Farzin
Hello, Dear EMC users
I read the getting started, Integrator, Hall and User manuals but I
could not find anything about 'Handwheel and how it could be connected to a
machine running with EMC2.
I need help on that. Thanks for all the help and guidance so far.
Farzin
Dear EMC users,
As you know when running a program, we can stop the program run by
clicking on Stop button. Now by clicking the Stop button, if spindle is also
running during the program run it stops
turning too. Is there anyway that if we click on the Stop button, we stop
the program from
Hi Steve,
During the period between PC on and machine on, some of the parallel port
pins are on which make some outputs on. How do I know which pins are on
during that period and which pins are off. This is all before the time EMC
starts. Thanks
Farzin
On Sat, Jan 29, 2011 at 1:03 PM, Steve
Dear Emc users,
Would you please help me find specifications for something like :
emc.stat.settings[0], [1], [2], etc.
I am new to emc and sorry for low level questions. I am trying to get
stronger on both Linux and emc. Thanks,
Farzin
Dear EMC users,
I was wondering how I can find the specs for somethings like
emc.stat.settings[0]. I need a thorough descriptions for some stuff to have
a better understanding of what is happening.
Thanks for your help,
Farzin
Dear EMC users,
I am using the cable shield and the input pins of the parallel ports to
make any input on or off. When the shield is not connected to the input pin
it is on or in 1 state and when it is connected to the pin it makes the pin
off or have zero level. Now my concern is that how
Dear EMC users,
I was going to show the commanded feed from the Gcode program in the AXIS
Gui. This way we could see feed from Gcode instructions like F1000 somewhere
in terms of unit length
per minute. Would you please let me know how I can read this from something
like emc.stat.??? updated all
Hello folks,
I was going to show the commanded feed in unit length per minute from the
Gcode (Fxxx) on Axis graphics. As you know we have the actual feed
calculated from the current velocity
reading from emc.stat.current_vel which is in unit length per second. Now
how can I read the commanded
Hello guys,
I have a question regarding an output signal on the parallel port. I need
to know how I can interface an output signal on the parport with for
instance a signal on a drive for spindle.
For example I have a 0 and five volt signal on pin-2-out and I want to use
it to turn spindle
Dear Sirs,
I would like to change and modify some of the English language messages,
notifications,
and I also need to know how to rebuild the emc software, using makefiles.
I need help on
how to do that. What are the ingredients of the emc software to build it?
What parts can I
configure or
Hello Jeff,
I am new to the EMC and the source code and the source tree. I still do
not have git installed on my computer and do not know what version of git I
should use and install and
do not know if I really need git installed to search for the error messages.
I could not find the
control.c
Dear Sirs,
I am going to change some error messages from emc. These errors are
generated when we poll the emc.error_channel. I just need
to know where these error messages are coming and read from, so I
could change their texts to make them clearer. Thanks for the help.
F.Kamangar
31 matches
Mail list logo