), 7 (data loss), 90 (system status) and others only have the
4-char SMFID. For example it is non-trivial to match which SYSA IPL was related
to which z/OS image with SMFID of SYSA.
Al Sherkow
--
For IBM-MAIN subscribe / signoff
It is computed for the same time period.
Al
--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN
other LPARs. I used these fields to determine if the LPAR was
running z/OS. VM images showed up differently; I don't recall how a CF LPAR
using GCPs showed up.
Al Sherkow
I.S. Management Strategies, LTD.
--
For IBM-M
I had problems to solve to combine old SMF records (0/IPL, 90(5A)/System
Status) when 4-char SMFID/SYSPLEX/SYSNAME are duplicated on different machines
as the CPUTYPE and serial number are not in most of the SMF records. I did ask
IBM to add those to the SMF header some time ago. I think through
I don't consider myself a "systems programmer" any longer... I assume the only
safe way to do this is with an IPL. I don't know if changing this dynamically
is an option. There will be no issue with SCRT. SYSNAME is in both the SMF 70
and SMF 89 records that SCRT processes. SCRT can handle chang
SMF89 record.)
Most of my licensees have 4-char SMFID=SYSNAME. I have a few customers where
they are different. As others have written some sites have found interesting
uses for the extra four characters in SYSNAME.
Al Sherkow, I/S Management Strategies, Ltd.
+1 414 332-3062
www.sherkow.com
u may reduce a
peak, but as Scott wrote, the latent demand or other factors in the workload
just move the peak. At many sites the monthly 4HRA peaks are not predictable.
Al Sherkow
I/S Management Strategies, ltd.
--
For IBM
I agree with Scott. That is what I was going to recommend to you also.
Al
--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN
Mario & Cheryl
Thank you! This is useful and works as you described!
Best regards, Al
--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN
ge occurred for
further investigation.
None of my customers have discussed a similar issue with me.
Best regards, Al Sherkow
--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.
be in some other SW tools).
My licensees have a list of VUE and licensed functions for Excel to do MSU to
VUE conversions, and also VUE to MSU conversions so they can build a site
specific product, MSU, VUE tracking workbook.
Al Sherkow, I/S Management Strategies, Ltd.
Consulting Expertise on
Yes, the DEV/TEST container is no longer included in the Simultaneous 4HRA.
--
Al Sherkow, I/S Management Strategies, Ltd.
Consulting Expertise on
WLC, LPARs and LCS Software
Seminars on IBM SW Pricing
+1 414 332-3062
--
For
SCRT reports. There is a big backend
infrastructure that IBM built. (I know because I've emulated their backend to
generate estimated invoices in my LCS product). SCRT leads to a monthly
invoice, and few ISVs take monthly data from a customer today and generate an
invoice.
Al Sh
zIIP capacity to their
machines. This is just one more way my tool, LCS, has been helping sites save
money since 2003!
Al Sherkow, I/S Management Strategies, Ltd.
Consulting Expertise on IBM Workload License Charges (WLC) and LCS Software
Seminars on IBM Mainframe Software Pricing
+1 414 332-
t I don't require a license key for the daily data extraction
and collection process. The license key is only used during analysis, reporting
and auditing of SCRT.
Al Sherkow, I/S Management Strategies, Ltd.
Consulting Expertise on IBM Workload License Charges (WLC
ation in now rather than later. I
do know sites that have transactions that work for tradition and Mobile work
that have "cloned" the transaction for Mobile to make that more easy to
identify. The "routing" uses the traditional transaction or the mobile
transaction.
Al S
Minor point: April 10, 2017 will bring a new release of SCRT, not a new
Version. Customers are required to use the most recent version but you do not
need to install an SCRT release unless you need the functionality of that
release.
Al Sherkow, I/S Management Strategies, Ltd.
Consulting
Of course LCS will be updated to support this new functionality for my
licensees!
Al Sherkow, I/S Management Strategies, Ltd.
Consulting Expertise on IBM Workload License Charges (WLC),
LPARs and LCS Software
Seminars Since 2003 on IBM Mainfra
kload is growing overtime you should be OK. IF your workload is
shrinking then CMP may not save you money, and could cost you money. Again, the
rules are complicated.
Al
Al Sherkow, I/S Management Strategies, Ltd.
Consulting Expertise on IBM Workload License Charges (WLC) and LCS Software
Se
RMF will be in the PRODFEAT fields of TYPE89-2 (PDB.TYPE892 in MXG) but SCRT
does not read that field and SCRT does not report that fields. In the same
records, the PRODREGS should be zero if you are not using RMF.
Al Sherkow, I/S Management Strategies, Ltd.
Consulting Expertise on IBM Workload
invoice shows RMF, then IBM's license data needs to be
corrected.
Al Sherkow, I/S Management Strategies, Ltd.
Consulting Expertise on IBM Workload License Charges (WLC),
LPARs and LCS Software
Seminars on IBM Mainframe Software Pricing
+1 414 332-3062
www.sherko
fixes
an ABEND S02 when using multiple SMF datasets having different LRECLs." See
<http://ibm.com/systems/z/resources/swprice/subcap/scrt/new.html> for more
information on today's update.
Al Sherkow, I/S Management Strategies, Ltd.
Consulting Expertise on IBM Workload License Cha
ous 4HRA of
your sub-capacity software products.
Al Sherkow, I/S Management Strategies, Ltd.
Consulting Expertise on IBM Workload License Charges (WLC),
LPARs and LCS Software
Seminars on IBM Mainframe Software Pricing since 2003!
+1 414 332-3062
www.sherkow.com
---
ment
letter 215-230 dated July 28, 2015.
Al Sherkow, I/S Management Strategies, Ltd.
Consulting Expertise on IBM Workload License Charges (WLC)
Seminars on IBM Mainframe Software Pricing
+1 414 332-3062
--
For IBM-MAIN sub
es other SMF records to
determine if an IPL occurred and whether it was preceded with a HALT EOD
command or not. Additionally LCS audits the SCRT or MWRT CSV output files and
the resultant IBM invoice.
Al Sherkow
I/S Management Strategies, Ltd.
Consulting Expertise on IBM Workload License Charge
zNALC paperwork and recertifying that the LPARs still qualify for zNALC.
Regards, Al
--
Al Sherkow, I/S Management Strategies, Ltd.
Consulting Expertise on IBM Workload License Charges (WLC),
Seminars on IBM Mainframe Software Pricing
+1 414 332-3062
d that someone else has been
successful with the particular vendors, and that is good information to have.
Al Sherkow, I/S Management Strategies, Ltd.
Consulting Expertise on WLC, & LCS Software
Seminars on IBM SW Pricing
+1 41
Putting a hard cap on an LPAR limits the LPAR's use of the CPU; it does not
limit a single application.
Yes you specify that on the HMC. 5% of 2000 is 100.
Al Sherkow, I/S Management Strategies, Ltd.
Consulting Expertise on IBM Workload License Charges (WLC),
LCS Software and
Semina
My analysis uses SMF data and is based only on public documentation of the SMF
data. I have to explain my analysis to customers and clients so anything I
might know under NDA is not useful in those circumstances.
If some vendor(s), as Ed wrote are using CPU and it is not marked as zXXP
eligibl
study entire
months. (The weird months that begin on the 2nd and end on the 1st).
LCS reporting also includes analysis of what your bill would be without any
zXXP engines when you do have them. This shows the value the zXXPs are
providing month after month.
Al Sherkow, I/S Management Strategies
S estimate the invoice? So that was implemented. Now customers can
audit SCRT which is the input to the invoice, and the resultant invoice itself.
Best regards, Al
--
Al Sherkow, I/S Management Strategies, Ltd.
Consulting Expertise on IBM Workload License Charges (WLC),
LPARs and LCS Software
Semin
y the same as SCRT's calculated four hour
rolling average either.
--
Al Sherkow, I/S Management Strategies, Ltd.
Consulting Expertise on IBM Workload License Charges (WLC),
LPARs and LCS Software
Seminars on IBM Mainframe Softwar
The examples did not use anything exotic like that. This was "direct" attached
DASD and the write misses were occasionally half a second and that showed up in
the SMF42-6 data as that records average and maximum service times.
-
ed
how to use the SMF 42-6 data to better understand response time for cache hits
and cache misses.
Hard to believe that was 15 years ago that I did that work.
Al Sherkow
--
For IBM-MAIN subscribe / signoff / arch
Capacity Limits.
What does not work as you might expect is LPAR Group Capacity Limits and IRD
Weight Management, as IRD stops adjusting weights when the LPAR Group Capacity
Limit is limiting the group (or softcapping the group) .
Al Sherkow, I/S Management Strategies, Ltd.
Consulting Expertise
Capacity by itself. I'm
interested to continue the discussion of IRD and DC if someone wants to share
their experience.
Regards, Al
Al Sherkow, I/S Management Strategies, Ltd.
Consulting Expertise on IBM Workload License Charges
, to the LPARs that are
impacting more important work. This is what IRD weight management would do.
You can use both of these capabilities together, but you must understand that
weight management stops, as it is at the time the group cap "turns on".
Al Sherkow, I/S Management Strat
The "initial capping" checkbox on the HMC is the original (back to the 3090?)
PR/SM Hard Capping control. HardCapped LPARs do not work with Defined Capacity
or LPAR Group Capacity Limits.
Al Sherkow, I/S Management Strategies, Ltd.
Consulting Expertise on IBM Workload License Ch
ricing change I would
not expect any site to install a zEC12 for the "software" savings, but it is a
component of ROI and/or TCO.
Please see: http://bitly.com/14ePd7b or
http://www.sherkow.com/updates/tup_for_awlc_new_slopes_for_pricingplexes.html
Al Sherkow
I/S M
HW or SW Service
Units) does not really have any control over the Service Units. That is
controlled by whomever sets up WLM and how WLM, z/OS, and PR/SM manage each
machine.
Al Sherkow, I/S Management Strategies, Ltd.
Consulting Expertise on IBM Workload License Charges (WLC),
LPARs and LCS Sof
FWLC was introduced with Workload License Charges, z/OS and the z900. This is a
metric per footprint, regardless of the size of the machine. MVS DITTO V2
(5695-100) is one of these products. The price of FWLC products is not based on
the size of the full CPC MSU. This product is being increased
erheads of various configuration.
Barbara Nitz's post was right on. I agree with all of that. I don't recall
reading about her configuration of the sandplex, and I think that is a very
good idea.
Al Sherkow, I/S Management Strategies, Ltd.
Consulting Expertise on IBM Workload License
42 matches