Backup CFstruct

2003-03-21 Thread Dijkerman, E (Erik)
Listeners, Did one of you already setup a Backup strategy for your structures and wants to share this?? Regards, Erik Dijkerman X Rabobank ICT/Serverbedrijf PIM/OS390 ZL-S206400 Mailbox 17100, 3500 HG Utrecht *(030) 215 4878 *(030) 215 3085 ? [EMAIL PROTECTED] The

Re: Trigger Control-m job

2003-03-21 Thread mqm mqm
Can you explain in a bit more detail what you mean by triggering a Control-m job. Isn't Control-M the BMC scheduler? In which case you will be scheduling the batch jobs rather than triggering them. What platform are you on? mqm --- Burke Edward [EMAIL PROTECTED] wrote: Has anyone had any

Re: Shared Data Tables vs. Coupling Facility

2003-03-21 Thread mqm mqm
Hmmm, as an ex-CICS SysProg I should know this but it's been a while. There is a CICS list where you might get the answer. Register at [EMAIL PROTECTED] mqm --- regissr [EMAIL PROTECTED] wrote: Hi everybody, Please i have the following doubt : I'd like to know if CICS Shared Data

AW: Backup CFstruct

2003-03-21 Thread Raabe, Stefan
Hello, here is a sample what you could do using netview or any other proper automation tool: do every hour if qmgr a available issue dis cfstruct(*) on qma else if qmgr b available issue dis cfstruct(*) on qmb endif issue backup cfstruct for every structure on proper

Re: A question on MQ and J2EE

2003-03-21 Thread Gonzalo Diethelm
Thanks to everybody who responded. I'm leaning toward option C, hence this additional question. From: Rodrigo Vargas Sent: Thursday, March 20, 2003 19:57 Subject: Re: A question on MQ and J2EE Since you are using EJBs, you should be running on a J2EE server, consider using a Message Driven

Re: MQSI 2.1 aggregate reply looping when error downstream

2003-03-21 Thread Rodríguez Alvarez-Querol, Manuel Carlos
Hi Pierre, While reading your email the error looks familiar but when I saw the code everything looks fine. But when I took I closer look I saw in your code a really small detail which I think, could be the wrong thing. In your compute node you are building a wrong XML message. I noticed you

Anyone tried putting large messages with Paul Clarke's Q program?

2003-03-21 Thread Nigel Phelan
Hi all - posted for a colleague in the hope someone knows the answer off the top of their head: ...Has anybody actually gotten q to send very large messages? If I try using various files it either splits it into lines or gets a Hconn error. % ./q -oBLAST -m minbar -=999 -f q MQSeries Q

Re: Anyone tried putting large messages with Paul Clarke's Q program?

2003-03-21 Thread Kulbir S. Thind
You seem to be passing in 'q' as an argument to the -f switch, does that mean you're trying to put the contents of the 'q' utility on as a MQ message? What is the -=999 parameter for? Nigel Phelan [EMAIL PROTECTED] Sent by: MQSeries List [EMAIL PROTECTED] 21-Mar-2003 14:40 Please

Re: Anyone tried putting large messages with Paul Clarke's Q program?

2003-03-21 Thread Paul Clarke
You seem to be passing in 'q' as an argument to the -f switch, does that mean you're trying to put the contents of the 'q' utility on as a MQ message? What is the -=999 parameter for? Kulbir, The '-=' parameter tells queue to accept truncated messages larger than this value, this is used

Candle Command Centre and MQSeries

2003-03-21 Thread Herd, Stewart
First let me explain that in the MTSP QMGR we have MQ channels going out to: AAR_MTSP.AAR_AARP AAR_MTSP.AAR_MTST AAR_MTSP.CCRA_TITAN AAR_MTSP.CNR_MCP2 AAR_MTSP.CPR_MQP2 MTSP.TO.MQOHUXP1.BIN MTSP.USCS_MQB1 SGRC.MTSP.ZCC1 All except the top 2 are in remote

Re: Candle Command Centre and MQSeries

2003-03-21 Thread Rick Tsujimoto
I defined a situation that traps the INDOUBT event and assigned it as a warning (yellow), so Operations basically ignores it. I suppose you could assign it as a Not Monitored situation via the MQSeries Manager template, or delete/stop the situation if you do not wish to get any alerts at all.

MQ Multithreading

2003-03-21 Thread Dean Montevago
Hi, We have a CICS (S390 == AIX) LU6.2 application that is multithreaded with up to 8 tranactions. This is being converted to MQ. Can you do multithreading with MQ ? If so, any ideas on how to go about it. TIA Dean Dean Montevago Sr. Software Specialist Visiting Nurse Service of N.Y. phone :

FW: Candle Command Centre and MQSeries

2003-03-21 Thread Thomas, Don
Stewart, I've also seen Candle throw out alerts about the channel in doubt status. What I learned was that everytime MQ attempts to start a channel there is small period of time when the channel will be in doubt. This occurs as the MCA's work through their hand shaking. I was not able to

Re: Candle Command Centre and MQSeries

2003-03-21 Thread Glen Shubert
What do you have specified as the interval for the situation? We very seldom see in-doubts thru CCC, but we set the interval to 1 minute. Glen Shubert Herd, Stewart [EMAIL PROTECTED] Sent by: MQSeries List [EMAIL PROTECTED] 03/21/2003 11:22 AM Please respond to MQSeries List

Re: Data conversion on mainframe

2003-03-21 Thread Darren Douch
Ruzi the connection handle in a CICS app isn't a 'normal' connection handle - it is actually the CICS region itself is connected to the qmgr, CICS just lets the application use one of these handles. The contents of the handle are 0 - before and after - and that is normal. I really think this is

Re: Running different versions of MQ

2003-03-21 Thread Miokovic, Nick
Title: Running different versions of MQ Stewart: We are running the same configuration. Early Code is loaded in the LPA, so youd include your thqual.SCSQLINK library in an LPALSTxx member of SYS1.PARMLIB. This library does not have to be in linklist. As for your thqual.SCSQAUTH, its

Re: MQ Multithreading

2003-03-21 Thread Darren Douch
Dean MQ is inherently asynchronous - your CICS and AIX apps will not be talking directly to each other in the way that they do with LU6.2 - although message transfer times can be quick enough to make MQ look synchronous. Your apps can have any number of threads getting / putting msgs at the same

Re: Increase size of error logs

2003-03-21 Thread Aatush Desai(PIPEX)
Title: RE: Increase size of error logs My friend found the following on IBMLINK:- 1. ERROR DESCRIPTION: Customer requests that the size of the error logs be either larger or (better) changeable. The current size defaults to 256Kb but he wants to be able to manually change the default size

Register IBM MSCS Resource Type with MSCS - wmq5.3

2003-03-21 Thread jesse h. goode jr.
wmq5.3 was installed on (2) individual nodes. These nodes were then MSCS Clustered. The IBM MSCS Resource Type is not listed as one of the available types. ( i.e. the .dll is not registered with MSCS ) . Anyone know how to get it registered? jesse goode jrvalero energy corporation[EMAIL

Re: Increase size of error logs

2003-03-21 Thread Stefan Sievert
Hi Aatush, I would assume that you'd have to set a global environment variable (ControlPanel-System) on Windoze platforms as well, wouldn't you? Just a guess, haven't tried it. Peace, Stefan From: Aatush Desai(PIPEX) [EMAIL PROTECTED] Reply-To: MQSeries List [EMAIL PROTECTED] To: [EMAIL