[sipx-users] Difference between sipx development version 3.11.11 and sipx version 4.0

2009-02-05 Thread Gmb
Hi, what are the difference between sipx development version 3.11.11 and sipx version 4.0? Is 3.11.11 a transition version to 4.0? If 3.11.11 is a transition version to 4.0 why in http://track.sipfoundry.org/browse/XECS the two versions have different bug? Thanks

Re: [sipx-users] Difference between sipx development version 3.11.11and sipx version 4.0

2009-02-05 Thread Tony Graziano
3.11.X versions are developer versions and are not stable. They will eventually increment and be refined at which point there will be a 4.0 stable/production release. Its not abnormal to have bugs in development versions that are being worked out and resolved. -Original Message-

[sipx-users] Inter Communication b/w two sipx?

2009-02-05 Thread VG
Hi Friends do we have the following facilty in sipx: Phone201 Phone 202 site A --- sipx1 Main Sipx3 Phone 301 Phone 302site B --- sipx2 Sipx3 will handle all the signaling and known to the state of each conversation occur in b/w siteA siteB as well as internal

Re: [sipx-users] Inter Communication b/w two sipx?

2009-02-05 Thread Picher, Michael
Vikas, You could setup your PBX in HA mode and run it as a single system. Also, Clustering should be a reality in version 4.0 allowing for any number of call processing servers... and better control over site selection of gateways. Mike -Original Message- From:

Re: [sipx-users] Calls dropping after 12 seconds

2009-02-05 Thread milosz
what version of the mediant firmware? what is your sip transport protocol set to on the mediant? have you tried setting up a syslog capture (with the acsyslog tool, for example)? On Thu, Feb 5, 2009 at 7:24 AM, Mitchell, Kenny (Ineos) kenny.mitch...@ineos.com wrote: Hi team, I saw a mail

[sipx-users] After upgrading from 3.10.3 Unable to make calls

2009-02-05 Thread Gilmour, Scott
All, I upgraded to 3.10.3 the other day and now I am unable to make calls with my Siemens Optipoint 410 advance phones. I even started from Factory Defaults and reconfigured my phones and the sipXecs Server and it still fails. When I go to make a call I get a message on my phone cleared unknown

Re: [sipx-users] Difference between sipx development version 3.11.11 and sipx version 4.0

2009-02-05 Thread Damian Krzeminski
Gmb wrote: Hi, what are the difference between sipx development version 3.11.11 and sipx version 4.0? Is 3.11.11 a transition version to 4.0? If 3.11.11 is a transition version to 4.0 why in http://track.sipfoundry.org/browse/XECS the two versions have different bug? Thanks

Re: [sipx-users] I can not make outgoing calls because of loop

2009-02-05 Thread rgxv zxv
Thanks for your answers. I solved my problem. It was a configuration issue that is related to SIP Trunk gateway. From: Dale Worley dwor...@nortel.com To: rgxv zxv erayg...@yahoo.com Cc: sipx-users@list.sipfoundry.org Sent: Thursday, January 29, 2009 8:11:32 PM

Re: [sipx-users] Calls dropping after 12 seconds

2009-02-05 Thread milosz
the full version id should look like this: Firmware Version 5.20A.042.003 you should have -at least- this version. previous versions have a kind of bizarre bug that causes problems with 3.10. the acsyslog tool is just a custom tool for capturing syslog output from the mediants. you

Re: [sipx-users] After upgrading from 3.10.3 Unable to make calls

2009-02-05 Thread Gilmour, Scott
Hi, I am still having no luck so is there a way to backrev to the previous firmware I had installed? Thanks Scott From: Gilmour, Scott Sent: Thursday, February 05, 2009 9:19 AM To: sipx-users@list.sipfoundry.org Subject: After upgrading from 3.10.3 Unable to make calls All, I upgraded to 3.10.3

Re: [sipx-users] After upgrading from 3.10.3 Unable to make calls

2009-02-05 Thread Scott Lawrence
On Thu, 2009-02-05 at 09:18 -0500, Gilmour, Scott wrote: All, I upgraded to 3.10.3 the other day and now I am unable to make calls with my Siemens Optipoint 410 advance phones. I even started from Factory Defaults and reconfigured my phones and the sipXecs Server and it still fails.

Re: [sipx-users] Triggering LDAP Imports to SipXecs via SOAP

2009-02-05 Thread Michael LeBlanc
Oh well, it looks like I spoke too soon -- it seems like some DB sanitization happens when sipXconfig is refreshed. As a result, my * 15 ? * * entry in cron_schedule gets reverted back 0 15 ? * * -- an hourly import. Any suggestions? I'm debating between writing a plugin for the directory

Re: [sipx-users] After upgrading from 3.10.3 Unable to make calls

2009-02-05 Thread Gilmour, Scott
Hi Steve, I am having ussues getting my sipViewer to display the information. My Sip server is 20.1.180.75 My users are 2000 and 3000 2000 = 192.168.5.100 3000 = 192.168.5.100 Vlan = 444 Thanks Scott -Original Message- From: Scott Lawrence [mailto:scott.lawre...@nortel.com] Sent:

Re: [sipx-users] Triggering LDAP Imports to SipXecs via SOAP

2009-02-05 Thread Damian Krzeminski
Michael LeBlanc wrote: Oh well, it looks like I spoke too soon -- it seems like some DB sanitization happens when sipXconfig is refreshed. As a result, my * 15 ? * * entry in cron_schedule gets reverted back 0 15 ? * * -- an hourly import. Any suggestions? I'm debating between writing a