Hi all,
I have tried several time to add ODBC datasource for a program. I'm
using firebird datasource and I have checked properties for driver.
What I'm doing wrong because the datasource doesn't get added?
This is the section where datasource is defined:
Media Id=1 Cabinet=Contents.cab
I can confirm that warnings are all okay for Vista logo... I have a number of
ICE33 warnings and have gotten that all important badge of approval for my
packages. You can also get away with errors that appear as aresult of
including MS merge modules, so long as they're well documented. The
Does running the application generate new files in your folder(s) and so the
installer has lost full ownership and so won't remove them? Try performing
a treewalk of your installation files and see if anything new shows up that
you weren't expecting.
--
View this message in context:
Nope. What I did to test was the following. Install files. After install
complete, uninstall. only the plugin directory was removed. The root
directory - StepCalc - Was not removed.
Any Ideas?
On 3/12/07, Gareth at Serif [EMAIL PROTECTED] wrote:
Does running the application generate new
Hi,
I'm using a quit execution custom action to hide a folder at the end of the
installation, the folder is created by the installation. The installation
doesn't fail but the folder attributes remain intact.
And on the msi log i can see the variable inside the [ ] is not resolved and
i guess it
Is there any place in particular where I should be making noise in
regards to getting a BOF or breakout session going?
Joel Peterson
Quality Engineer
[EMAIL PROTECTED]
From: Rob Mensching [mailto:[EMAIL PROTECTED]
Sent: Sunday, March 11, 2007 12:19 PM
To: Peterson, Joel;
How does Wix determine which control to set as control_first in the dialog
table? Is there a way to override this?
Thanks!
-Tina
-
Take Surveys. Earn Cash. Influence the Future of IT
Join SourceForge.net's Techsay panel and
It's the control that is listed first.
From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of Tina Basinger
Sent: Monday, March 12, 2007 9:11 AM
To: Wix Group
Subject: [WiX-users] Control_first
How does Wix determine which control to set as control_first in the dialog
table? Is there a
Heh, I hitchhiked my way into PDC last year (i.e. offered to do a lot of work
in exchange for a ticket in). Took a fair bit of work and WiX wasn't on the
official list of anything anywhere. I just wrote some stuff on a whiteboard
and spent a lot of time answer questions about it. That was
You're not going to be elevated at that point in time... you probably don't
have permissions to do that.
From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of Ricardo Lopes
Sent: Monday, March 12, 2007 7:33 AM
To: wix-users@lists.sourceforge.net
Subject: [WiX-users] Variable inside
I've never seen anyone do what you did, so I'm not much help. smile/
-Original Message-
From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of Gareth at Serif
Sent: Monday, March 12, 2007 4:58 AM
To: wix-users@lists.sourceforge.net
Subject: Re: [WiX-users] Broken shortcuts in
I think you need to re-read the Vista logo doc.
You can have more than 1 shortcut per component they just have to point
to the same file. Here is the NOTES section from Test Case 29.
1. The application's Windows Installer may contain more than one
shortcut for each component listed in the
Hey everyone,
Just getting my feet wet with WiX. I've been working my way through the
documentation and the online tutorial the past few days, but so far I've
not been able to figure out if WiX has the ability to create anything
like a global, reusable property, and if so, how are they applied?
Robert,
One way that you can accomplish the below is an include file (NOTE
includes are generally frowned upon).
As an example you could set a property with respect to a directory
search in the include
?xml version=1.0 encoding=utf-8?
Include
Robert,
One thing I'm not sure about... Are you saying that you want to be able
to change the property at runtime? If so, then I think what you are
suggesting may actually break the component rules (you would have the
same component, but multiple different filenames). I'm sure someone else
Richard - You're close...I don't want to be able to change anything at
runtime. What I want is a simple way to define a string variable that
will be used in several placed throughout the source file, and then
reference in some way wherever I need to use it. I'd like to do that so
that, if the
In that case, look at the Preprocessor section in the WiX help, it
describes the preprocessor variables (which was what I mentioned), and
also how a similar technique can be used to access environment variables
and system variables.
Be aware though, that the $(var.) format I mentioned is
Aahhh...the Preprocessor. That was what I was looking for. Thanks very
much.
__
// YEX //
From: [EMAIL PROTECTED]
[mailto:[EMAIL PROTECTED] On Behalf Of
[EMAIL PROTECTED]
Sent: Monday, March 12, 2007 4:35 PM
To:
You always find answers after you send the email. This looks like this was a
build issue.
Thanks,
- Matt
From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of Matt Coill
Sent: Monday, March 12, 2007 2:16 PM
To: wix-users@lists.sourceforge.net
Subject: [WiX-users] Can't run custom
Usually it means that the DLL has a dependency (e.g., msvc?80.dll) that
aren't being met, so MSI can't even load the DLL. Best solution: Build
CA DLLs with the static CRT. The VC80 runtime is installed as
assemblies, so they're not available even when deferred CAs run.
From: [EMAIL PROTECTED]
Hi, I have a COM component I am trying to register using wix. I am using this
type of syntax:
.
.
.
Registry Id=_64B01B48C18D4FF0A3C8E04A3ACF1587
I have a file specified this way
...
Directory Id=TARGETDIR Name=SourceDir
Directory Id=TempFolder Name=.
Directory Id=xusb Name=xusb
Component Id=xusb21_inf
Guid=363597DB-7BB5-4553-9D63-00273F9E958B
Answering my own question again; I am having a good day!
CustomAction Id=install_driver.SetProperty Return=check
Property=install_driver Value=[#xusb21_inf] /
This action should be set as:
InstallExecuteSequence
Custom Action=install_driver.SetProperty
Anzi wrote:
MSI (s) (68:74) [10:03:09:630]: Doing action: InstallODBC
Toiminta alkoi 10:03:09: InstallODBC.
MSI (s) (68:74) [10:03:09:630]: Note: 1: 2711 2: ODBCDriverManager64
I don't know anything about installing ODBC data sources, but see
Jason Erickson wrote:
Nope. What I did to test was the following. Install files. After
install complete, uninstall. only the plugin directory was removed.
The root directory - StepCalc - Was not removed.
Any Ideas?
Take a look at a verbose install log around the CostFinalize and
Maslov, Igor wrote:
What I'm doing wrong? Is it possible to get a disk prompt message
instead of missing file message?
http://msdn2.microsoft.com/en-us/library/aa367782.aspx says you need
error 1302 authored into the Error table. Are you doing that? If so,
what does a verbose log show
26 matches