HI Strahil,
I am also running into an issue trying to replace a brick.

1.-/dev/sdd failed which is our /gluster_bricks/data2/data2 brick, hat disk was 
taken out of the array controller and added a new one.

2.-there are quite a bit of entries related to /dev/sdd , i.e.

[root@host1]# dmsetup info  |grep sdd
Name:              gluster_vg_sdd-gluster_thinpool_gluster_vg_sdd-tpool
Name:              gluster_vg_sdd-gluster_thinpool_gluster_vg_sdd_tdata
Name:              gluster_vg_sdd-gluster_thinpool_gluster_vg_sdd_tmeta
Name:              gluster_vg_sdd-gluster_thinpool_gluster_vg_sdd
Name:              gluster_vg_sdd-gluster_lv_data2

this causes the OS to see the new disk as /dev/sde (the controller presents it 
as /dev/sde)

array C

      Logical Drive: 3
         Size: 2.7 TB
      ...
         Disk Name: /dev/sde 
         Mount Points: None
         .....
         Drive Type: Data
         LD Acceleration Method: Controller Cache

If i just remove all the thinpool entries (if i find them) do you think that 
might do the trick?

thanks,

Adrian