These would make excellent absortion refrigerators and air conditioners
which may be more efficient than going the electric route.

In the Platen-Munters system, (
http://www.absreftec.com/downloads/chapter01.pdf ), ammonia water is freed
of it's amonia by heat which is condensed into liquified amonia gas.

In the liquid dessicant system, lithium bromide solution is regenerated to a
saturated solution by heat, which then absorbs the water out of humid air,
which is then cooled by evaporating water into it (
http://faculty.ucmerced.edu/gdiaz/resume/JIJR_2011.pdf

  -----Original Message-----
  From: Jed Rothwell [mailto:jedrothw...@gmail.com]
  Sent: Saturday, July 02, 2011 1:50 PM
  To: vortex-l@eskimo.com
  Subject: Re: [Vo]:Lots of good information in Defkalion forum, mixed in
with lots of nonsense


  Here is some of the information from the forum gathered into a single
document:


  http://ecatreport.com/hyperion/defkalions-hyperion-unit-equipped-with-gsm


  It says, for example:


  Question: What is the maximum temperature of steam that can be produced
using Hyperion?
  Answer: In a Hyperion/external heat exchanger system, the maximum
temperature we can get for the steam at the heat exchanger output is 414C.