Thanks - that works perfectly!
Removing the CDATA makes it compile. When I install it on WinXP the dll is
not installed, but on Win2k it is - just like I wanted.
The component is now:
<Component Guid="{..}" Id="C_GDI">
<Condition>VersionNT=500 Or NOT Version9x=""</Condition>
<File DiskId="1" Id="id1893" KeyPath="yes" Name="gdiplus.dll" Vital="yes"
src="gdiplus.dll" />
</Component>
Thanks for helping!
John Vottero wrote:
>
> Yes, you still have access to VersionNT and Version9X. Try making your
> condition:
>
> <Condition>VersionNT=500 Or NOT Version9x=""</Condition>
>
--
View this message in context:
http://www.nabble.com/GDI%2B-MergeModule-tf4316091.html#a12394849
Sent from the wix-users mailing list archive at Nabble.com.
-------------------------------------------------------------------------