We've just started using Clearfield pre-made pushable or strong fiber spools pulled through 10/6 duct up to the radio. We use BiDi so just one strand but if you wanted a feed to a tower top they could make you MPO cables that you could route to a YourX terminal up top through 14/10.
I wish someone made a 10/6 duct with copper conductors on the outside of it. Like Clearfield s toneable 10/6 except with two larger conductors under the outer wrap instead of the single small tone wire. Would be perfect for Siklu instals as you could run the duct right into their long connector and split off the conductors to power the radio. On Thu, Dec 27, 2018 at 9:21 AM dave <dmilho...@wletc.com> wrote: > We use Bestronics custom hybrid cable pre-terminated armor direct bury > type. Has 1 pair 12awg stranded and 2 pair SM or MM strands. Been doing it > for a while with no issues. > > Just did 250 full medusa install with DDB cabinet topside for all > terminations to go. > > > On 12/20/18 2:02 PM, SmarterBroadband wrote: > > What are people using for Fiber up the tower? > > > > We are looking for Single mode 4 strand – 2 LC Duplex at each end. 140 > foot lengths. They will be run up inside a monopole. > > > > Are you using armored? Outdoor? What? > > > > Where are people getting theirs made? > > > > Thanks > > > > Adam > > -- > AF mailing list > AF@af.afmug.com > http://af.afmug.com/mailman/listinfo/af_af.afmug.com > -- Carl Peterson *PORT NETWORKS* 401 E Pratt St, Ste 2553 Baltimore, MD 21202 (410) 637-3707
-- AF mailing list AF@af.afmug.com http://af.afmug.com/mailman/listinfo/af_af.afmug.com