Dude, I'm seeing multipath and ducting like a somebitch. Started around
dusk. Don't beat your head into your desk. I'm seeing some 11GHz links
go from their nominal -45ish to like -35 to -60 in just a couple
minutes, and BER alarms like crazy. This is teh suck.
On 10/6/2016 8:47 PM, That One Guy /sarcasm wrote:
There is some nutty madness going on on a large portion of our 320
network, it has hit multiple sites at once.
I know much of its self induced due to too many marginal installs on
very limited access points
good CINR to SMs, even matrix B I cant even get into to manage.
uplink MCS for the most part looks good until i get into the frame
utilization, tons of 16qam 1/2 and 100% usage with only 6-12 mbps
throughput
I have been shifting frequencies across the network because it
presented like interference, and a change on one AP results in
required cascade changes across the 3ghz network since 320 sync doesnt
actually work.
APs are basically default layer 2, no profiles changed, 7mhz channels
mostly ABCD 90s and some split APs. sub counts range from 10 to 35
I migrated a distant part of the network to 10mhz channels and am not
seeing this issue, but subscriber counts are low
Im at my wits end on this nonsense and am about to just put every AP
on the network in SA mode to get a visual on what my spectrum looks like
we did turn up a 450 facing southwest ten miles south of another 320
AP thats facing south, it blinded the SMs to the 320 on a near channel
even though they were only in the back lobe, but this is far from the
others
any advice from you other guys stuck with wimax would be appreciated
--
If you only see yourself as part of the team but you don't see your
team as part of yourself you have already failed as part of the team.