I am going to fix this little problem...

Netonix will fix your port for something like $25

From: Bill Prince 
Sent: Friday, March 24, 2017 8:56 PM
To: [email protected] 
Subject: Re: [AFMUG] Fw: Netonix

Yeah. We accidentally hooked up an AF24 through a Cambium surge suppressor, and 
it fragged the port on the Netonix. We were swapping from something else that 
had been on the cable, and completely forgot that it was going through that 
surge suppressor. Hard lesson learned.


bp
<part15sbs{at}gmail{dot}com>

On 3/24/2017 1:27 PM, Chuck McCown wrote:

  OK,  had an exchange with Netonix today.  It is just as Matt Hoppes said.  
You short out their POE and it will blow the Ethernet transformer.  

  I really presumed they had circuitry like Forrest that could detect and shut 
down in an over current situation.  They do have poly fuses which are slow to 
react and may protect it from a very brief short, but longer shorts will indeed 
harm the port feeding the transformer.  

  So, Netonix is not active POE.  I would say that on passive POE a plain surge 
suppressor should not be used.  I am working some “non plain” surge suppressors 
now.... ;-)  Stay tuned to this bat channel and a big thanks to Matt for 
forcing me to learn something new.  It was painful, but I can do painful things 
when I have to.  

  From: Chuck McCown 
  Sent: Friday, March 24, 2017 10:01 AM
  To: [email protected] 
  Subject: Re: [AFMUG] Netonix

  tnx

  From: Josh Luthman 
  Sent: Friday, March 24, 2017 9:47 AM
  To: [email protected] 
  Subject: Re: [AFMUG] Netonix

  chris.sisler 
  ( A )

  netlinx.net


  Josh Luthman
  Office: 937-552-2340
  Direct: 937-552-2343
  1100 Wayne St
  Suite 1337
  Troy, OH 45373

  On Fri, Mar 24, 2017 at 11:45 AM, Chuck McCown <[email protected]> wrote:

        Anyone know the email for the guy that runs Netonix?


Reply via email to