I am going to fix this little problem... Netonix will fix your port for something like $25
From: Bill Prince Sent: Friday, March 24, 2017 8:56 PM To: [email protected] Subject: Re: [AFMUG] Fw: Netonix Yeah. We accidentally hooked up an AF24 through a Cambium surge suppressor, and it fragged the port on the Netonix. We were swapping from something else that had been on the cable, and completely forgot that it was going through that surge suppressor. Hard lesson learned. bp <part15sbs{at}gmail{dot}com> On 3/24/2017 1:27 PM, Chuck McCown wrote: OK, had an exchange with Netonix today. It is just as Matt Hoppes said. You short out their POE and it will blow the Ethernet transformer. I really presumed they had circuitry like Forrest that could detect and shut down in an over current situation. They do have poly fuses which are slow to react and may protect it from a very brief short, but longer shorts will indeed harm the port feeding the transformer. So, Netonix is not active POE. I would say that on passive POE a plain surge suppressor should not be used. I am working some “non plain” surge suppressors now.... ;-) Stay tuned to this bat channel and a big thanks to Matt for forcing me to learn something new. It was painful, but I can do painful things when I have to. From: Chuck McCown Sent: Friday, March 24, 2017 10:01 AM To: [email protected] Subject: Re: [AFMUG] Netonix tnx From: Josh Luthman Sent: Friday, March 24, 2017 9:47 AM To: [email protected] Subject: Re: [AFMUG] Netonix chris.sisler ( A ) netlinx.net Josh Luthman Office: 937-552-2340 Direct: 937-552-2343 1100 Wayne St Suite 1337 Troy, OH 45373 On Fri, Mar 24, 2017 at 11:45 AM, Chuck McCown <[email protected]> wrote: Anyone know the email for the guy that runs Netonix?