Hi Marko, Port fa0/0.211 of on R2 is encapsulating DOT1Q for VLAN 211. Whereas Port fa0/1.52 of on R5 is encapsulating DOT1Q for VLAN 52. Since the VLANS are Tunneled using the AToM Switch SW1 end up receiving BPDU's of SW3 for VLAN52 on the port connected to R2 (VLAN211) and vice-verse. I guess BPDU filtering will be a solution. I will try it out.This is my analysis to the situation. Let me know whats yours.
On the other hands, I worked on this LAB on Procotor Labs VRacks I never faced this issue with inconsistencies. Why? Please provide your feedback. Best Regards, Saleh Hassan Batouq [email protected] On Tue, Sep 3, 2013 at 8:00 PM, Marko Milivojevic <[email protected]>wrote: > Without straight-out giving you an answer (tell me if you want that), > let's try to understand the problem first… > > What do you think is causing this inconsistency? > > -- > Marko Milivojevic - CCIE #18427 (SP R&S) > Senior CCIE Instructor / Managing Partner - IPexpert > > > On Tue, Sep 3, 2013 at 8:36 AM, Saleh Batouq <[email protected]>wrote: > >> WB3-Lab9 >> -------- >> Task: L2VPN >> ------ >> >> >> I am running this on GNS, I have the AToM properly configured and >> functional. >> >> BUT I get Inconsistency messege on Cat1 & Cat3 >> >> Any suggestion on over-riding this inconsistency? >> >> >> >> >> The following are the outputs of show commands: >> >> >> >> >> On R2 >> ----- >> >> R2#sh mpls l2transport vc >> >> Local intf Local circuit Dest address VC ID >> Status >> ------------- -------------------------- --------------- ---------- >> ---------- >> Fa0/0.211 Eth VLAN 211 70.18.115.5 25 UP >> >> >> On R5 >> ------ >> >> R5#sh mpls l2transport vc >> >> Local intf Local circuit Dest address VC ID >> Status >> ------------- -------------------------- --------------- ---------- >> ---------- >> Fa0/1.52 Eth VLAN 52 70.18.115.2 25 UP >> >> >> >> >> >> BUT I get Inconsistency messege on Cat1 & Cat3 >> -------------------------------------------------- >> >> >> On Cat1 >> ------- >> >> Cat1(config)# PVST+:Inconsistency timer expired. inconsistency 2 >> cleared for FastEthernet1/2 >> >> *Mar 1 01:44:56.119: %SPANTREE-2-RECV_PVID_ERR: Received BPDU with >> inconsistent peer vlan id 52 on FastEthernet1/2 VLAN211. >> *Mar 1 01:44:56.119: %SPANTREE-2-BLOCK_PVID_LOCAL: Blocking >> FastEthernet1/2 on VLAN211. Inconsistent local vlan. >> >> >> >> Cat1#sh spanning-tree inconsistentports >> >> Name Interface Inconsistency >> -------------------- -------------------- ------------------ >> VLAN211 FastEthernet1/2 Port VLAN ID Mismatch >> >> Number of inconsistent ports (segments) in the system : 1 >> >> On Cat3 >> ------- >> >> [OK] >> Cat3# >> *Mar 1 01:44:49.487: %SPANTREE-2-RECV_PVID_ERR: Received BPDU with >> inconsistent peer vlan id 211 on FastEthernet1/5 VLAN52. >> *Mar 1 01:44:49.487: %SPANTREE-2-BLOCK_PVID_LOCAL: Blocking >> FastEthernet1/5 on VLAN52. Inconsistent local vlan. >> >> >> Cat3#sh spanning-tree inconsistentports >> >> Name Interface Inconsistency >> -------------------- -------------------- ------------------ >> VLAN52 FastEthernet1/5 Port VLAN ID Mismatch >> >> Number of inconsistent ports (segments) in the system : 1 >> >> Best Regards, >> >> Saleh Hassan Batouq >> [email protected] >> _______________________________________________ >> For more information regarding industry leading CCIE Lab training, please >> visit www.ipexpert.com >> >> Are you a CCNP or CCIE and looking for a job? Check out >> www.PlatinumPlacement.com >> >> http://onlinestudylist.com/mailman/listinfo/ccie_rs >> > > _______________________________________________ For more information regarding industry leading CCIE Lab training, please visit www.ipexpert.com Are you a CCNP or CCIE and looking for a job? Check out www.PlatinumPlacement.com http://onlinestudylist.com/mailman/listinfo/ccie_rs