That's not it :-). I mean, yes, BPDU Filter will "fix" the problem, i.e.
make it disappear, but that's not the cause.

Now - why you haven't encountered this before, I do not know. I even can't
recall if this is actually part of the lab, but it's an interesting problem
nevertheless. Something that's entirely possible to face in the lab.

Again, hint - it's not AToM error. It's something else. Read the error
message.

--
Marko Milivojevic - CCIE #18427 (SP R&S)
Senior CCIE Instructor / Managing Partner - IPexpert


On Tue, Sep 3, 2013 at 11:35 AM, Saleh Batouq <[email protected]> wrote:

> Hi Marko,
>
> Port fa0/0.211 of on R2 is encapsulating DOT1Q for VLAN 211. Whereas Port
> fa0/1.52 of on R5 is encapsulating DOT1Q for VLAN 52. Since the VLANS are
> Tunneled using the AToM  Switch SW1 end up receiving BPDU's of  SW3 for
> VLAN52  on the port connected to R2 (VLAN211) and vice-verse. I guess BPDU
> filtering will be a solution. I will try it out.This is my analysis to the
> situation. Let me know whats yours.
>
> On the other hands, I worked on this LAB on Procotor Labs VRacks I never
> faced this issue with inconsistencies. Why?
>
> Please provide your feedback.
>
>
> Best Regards,
>
> Saleh Hassan Batouq
> [email protected]
>
> On Tue, Sep 3, 2013 at 8:00 PM, Marko Milivojevic <[email protected]>wrote:
>
>> Without straight-out giving you an answer (tell me if you want that),
>> let's try to understand the problem first…
>>
>> What do you think is causing this inconsistency?
>>
>> --
>> Marko Milivojevic - CCIE #18427 (SP R&S)
>> Senior CCIE Instructor / Managing Partner - IPexpert
>>
>>
>> On Tue, Sep 3, 2013 at 8:36 AM, Saleh Batouq <[email protected]>wrote:
>>
>>> WB3-Lab9
>>> --------
>>> Task: L2VPN
>>> ------
>>>
>>>
>>> I am running this on GNS, I have the AToM properly configured and
>>> functional.
>>>
>>> BUT I get Inconsistency messege on Cat1 & Cat3
>>>
>>> Any suggestion on over-riding this inconsistency?
>>>
>>>
>>>
>>>
>>> The following are the outputs of show commands:
>>>
>>>
>>>
>>>
>>> On R2
>>> -----
>>>
>>> R2#sh mpls l2transport vc
>>>
>>> Local intf     Local circuit              Dest address    VC ID
>>>  Status
>>> -------------  -------------------------- --------------- ----------
>>> ----------
>>> Fa0/0.211      Eth VLAN 211               70.18.115.5     25         UP
>>>
>>>
>>> On R5
>>> ------
>>>
>>> R5#sh mpls l2transport vc
>>>
>>> Local intf     Local circuit              Dest address    VC ID
>>>  Status
>>> -------------  -------------------------- --------------- ----------
>>> ----------
>>> Fa0/1.52       Eth VLAN 52                70.18.115.2     25         UP
>>>
>>>
>>>
>>>
>>>
>>> BUT I get Inconsistency messege on Cat1 & Cat3
>>> --------------------------------------------------
>>>
>>>
>>> On Cat1
>>> -------
>>>
>>> Cat1(config)# PVST+:Inconsistency timer expired. inconsistency 2
>>>                  cleared for FastEthernet1/2
>>>
>>> *Mar  1 01:44:56.119: %SPANTREE-2-RECV_PVID_ERR: Received BPDU with
>>> inconsistent peer vlan id 52 on FastEthernet1/2 VLAN211.
>>> *Mar  1 01:44:56.119: %SPANTREE-2-BLOCK_PVID_LOCAL: Blocking
>>> FastEthernet1/2 on VLAN211. Inconsistent local vlan.
>>>
>>>
>>>
>>> Cat1#sh spanning-tree inconsistentports
>>>
>>> Name                 Interface            Inconsistency
>>> -------------------- -------------------- ------------------
>>> VLAN211              FastEthernet1/2      Port VLAN ID Mismatch
>>>
>>> Number of inconsistent ports (segments) in the system : 1
>>>
>>> On Cat3
>>> -------
>>>
>>> [OK]
>>> Cat3#
>>> *Mar  1 01:44:49.487: %SPANTREE-2-RECV_PVID_ERR: Received BPDU with
>>> inconsistent peer vlan id 211 on FastEthernet1/5 VLAN52.
>>> *Mar  1 01:44:49.487: %SPANTREE-2-BLOCK_PVID_LOCAL: Blocking
>>> FastEthernet1/5 on VLAN52. Inconsistent local vlan.
>>>
>>>
>>> Cat3#sh spanning-tree inconsistentports
>>>
>>> Name                 Interface            Inconsistency
>>> -------------------- -------------------- ------------------
>>> VLAN52               FastEthernet1/5      Port VLAN ID Mismatch
>>>
>>> Number of inconsistent ports (segments) in the system : 1
>>>
>>> Best Regards,
>>>
>>> Saleh Hassan Batouq
>>> [email protected]
>>> _______________________________________________
>>> For more information regarding industry leading CCIE Lab training,
>>> please visit www.ipexpert.com
>>>
>>> Are you a CCNP or CCIE and looking for a job? Check out
>>> www.PlatinumPlacement.com
>>>
>>> http://onlinestudylist.com/mailman/listinfo/ccie_rs
>>>
>>
>>
>
_______________________________________________
For more information regarding industry leading CCIE Lab training, please visit 
www.ipexpert.com

Are you a CCNP or CCIE and looking for a job? Check out 
www.PlatinumPlacement.com

http://onlinestudylist.com/mailman/listinfo/ccie_rs

Reply via email to