I have two 2502s plugged into an IBM 8228 MSAU in a lab.  They are connected
with a 9 pin to Type 1 cable.  For some reason, I can't get the line to come
up.  When I do "show interface", I see the TokenRing0 as "initializing" and
"down".  I wait a second and it goes to "down" / "down", then back to
"initialize" / "down".  I admit, I don't know much about Token Ring, but
this should be fairly straight forward, right?

On each router config I have:

RouterA:
!
interface TokenRing0
 ip address 192.168.30.1 255.255.255.0
 ring-speed 16
!

RouterB:
!
interface TokenRing0
 ip address 192.168.30.2 255.255.255.0
 ring-speed 16
!

When I do "debug token events" I get this output on both routers:
%TR-3-OPENFAIL: Unit 0, open failed: Phys. Insertion, ring beaconing
%TR-3-BADSTART: Unit 0, Start completion and wrong idb state - state= 0
TR0: reset from 30559AE
TR0: txtmr: 0x0, msclk: 0x146EF494, qt: 0 (0ms)
starting.

Any ideas?  Thanks in advance for the help!
Matt