Don't you hate it when your trying to set up a Layer 3 scenario, but you get
stuck troubleshooting Layer 2 problems!?!?!?!

Thanks to everyone who posted and emailed suggestions.  Everything is
working now.  Some info that I probably should have included in the first
post was that I was plugged into Ports 1 &2 on the MSAU (but I also tried
Ports 7 & 8), and that the MSAU was giving a clicking sound in synch with
the routers giving debugging info - about once every 10 seconds.  Also, I
had tried each router individually and got identical results, and there are
no other stations plugged into this MSAU.

Basically, all I did to solve it was plug the cables into ports 3 & 4 on the
MSAU, and walk away for about an hour.  When I came back we were UP and UP!
I have since plugged the cables back into ports 1,2,7,and 8 and verified all
are working.

I'm guessing that either the ports were stuck (and they auto-reset
themselves - Is that possible?), or perhaps I just didn't push those type 1
connectors in far enough.  If there's any Token Ring gurus out there that
would like to post about what could possible cause a port to become stuck,
or if it's possible for them to auto-reset, I'm sure everyone would
appreciate it.

Thanks again for all the replies!  This list rulz!
Matt



""Matt Shell"" <[EMAIL PROTECTED]> wrote in message
8hsfuj$vfr$[EMAIL PROTECTED]">news:8hsfuj$vfr$[EMAIL PROTECTED]...
> I have two 2502s plugged into an IBM 8228 MSAU in a lab.  They are
connected
> with a 9 pin to Type 1 cable.  For some reason, I can't get the line to
come
> up.  When I do "show interface", I see the TokenRing0 as "initializing"
and
> "down".  I wait a second and it goes to "down" / "down", then back to
> "initialize" / "down".  I admit, I don't know much about Token Ring, but
> this should be fairly straight forward, right?
>
> On each router config I have:
>
> RouterA:
> !
> interface TokenRing0
>  ip address 192.168.30.1 255.255.255.0
>  ring-speed 16
> !
>
> RouterB:
> !
> interface TokenRing0
>  ip address 192.168.30.2 255.255.255.0
>  ring-speed 16
> !
>
> When I do "debug token events" I get this output on both routers:
> %TR-3-OPENFAIL: Unit 0, open failed: Phys. Insertion, ring beaconing
> %TR-3-BADSTART: Unit 0, Start completion and wrong idb state - state= 0
> TR0: reset from 30559AE
> TR0: txtmr: 0x0, msclk: 0x146EF494, qt: 0 (0ms)
> starting.
>
> Any ideas?  Thanks in advance for the help!
> Matt
>
>
> ___________________________________
> UPDATED Posting Guidelines: http://www.groupstudy.com/list/guide.html
> FAQ, list archives, and subscription info: http://www.groupstudy.com
> Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]
> ---


___________________________________
UPDATED Posting Guidelines: http://www.groupstudy.com/list/guide.html
FAQ, list archives, and subscription info: http://www.groupstudy.com
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]