Results of debug frame-relay lmi command:
Jul 23 12:26:08.515 EDT: Serial0/1(in): Status, myseq 31
Jul 23 12:26:08.515 EDT: RT IE 1, length 1, type 0
Jul 23 12:26:08.515 EDT: KA IE 3, length 2, yourseq 31, myseq 31
Jul 23 12:26:08.515 EDT: PVC IE 0x7 , length 0x6 , dlci 501, status 0x2 , bw
256000
Jul 23 12:26:08.515 EDT: PVC IE 0x7 , length 0x6 , dlci 508, status 0x2 , bw
64000
Jul 23 12:26:08.515 EDT: PVC IE 0x7 , length 0x6 , dlci 510, status 0x2 , bw
64000
Jul 23 12:26:18.496 EDT: Serial0/1(out): StEnq, myseq 32, yourseen 31, DTE
up
Jul 23 12:26:18.496 EDT: datagramstart = 0xF00218, datagramsize = 13
Jul 23 12:26:18.496 EDT: FR encap = 0xFCF10309
Jul 23 12:26:18.496 EDT: 00 75 01 01 01 03 02 20 1F
Jul 23 12:26:18.496 EDT:
Jul 23 12:26:18.512 EDT: Serial0/1(in): Status, myseq 32
Jul 23 12:26:18.512 EDT: RT IE 1, length 1, type 1
Jul 23 12:26:18.512 EDT: KA IE 3, length 2, yourseq 32, myseq 32
Jul 23 12:26:28.496 EDT: Serial0/1(out): StEnq, myseq 33, yourseen 32, DTE
up
Jul 23 12:26:28.496 EDT: datagramstart = 0xF00998, datagramsize = 13
Jul 23 12:26:28.496 EDT: FR encap = 0xFCF10309
Jul 23 12:26:28.496 EDT: 00 75 01 01 01 03 02 21 20
Jul 23 12:26:28.496 EDT:
Jul 23 12:26:28.512 EDT: Serial0/1(in): Status, myseq 33
Jul 23 12:26:28.512 EDT: RT IE 1, length 1, type 1
Jul 23 12:26:28.512 EDT: KA IE 3, length 2, yourseq 33, myseq 33
Jul 23 12:26:38.497 EDT: Serial0/1(out): StEnq, myseq 34, yourseen 33, DTE
up
Jul 23 12:26:38.497 EDT: datagramstart = 0x1078778, datagramsize = 13
Jul 23 12:26:38.497 EDT: FR encap = 0xFCF10309
Jul 23 12:26:38.497 EDT: 00 75 01 01 01 03 02 22 21

----- Original Message -----
From: "Farhan Ahmed" 
To: "'Jeff'" ; 
Sent: Monday, July 23, 2001 9:24 AM
Subject: RE: FrameRelay Over Utilized [7:13349]


> send me debug frame-relay lmi output
>
> -----Original Message-----
> From: Jeff [mailto:[EMAIL PROTECTED]]
> Sent: Monday, July 23, 2001 5:20 PM
> To: [EMAIL PROTECTED]
> Subject: FrameRelay Over Utilized [7:13349]
>
>
> Hello,
> If I have a frame relay switch which is being over utilized will that
cause
> the connection to drop.  After looking in the log I see dlci 501 state
> changed
> to inactive, line protocol on interface s0/0.1 changed to down, dlci 501
> active, this keeps going and going through out the log.  The local telco
> insists that the circuit is overutilized and this is why the connection is
> dropping.  I think it is a telco or csu problem.  Also doing a show
> interface
> is showing 3000 crc errors and 500 interface resets for the past 3 days.
Is
> there any way to tell for sure whether it is overutilization or a telco
> problem??




Message Posted at:
http://www.groupstudy.com/form/read.php?f=7&i=13387&t=13349
--------------------------------------------------
FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]

Reply via email to