----[Please read http://ercoupers.com/disclaimer.htm before following any advice in this forum.]----
Ken, You are covered under the CARs see below (Erco) 415-D (Erco) E (Erco) G (Forney) F-1 (Forney) F-1A (Alon) A-2 (Alon) A2-A (Mooney) M10 August 12, 1994 Univair Aircraft Corporation 2500 Himalaya Road Aurora, Colorado 80011 Specifications Pertinent to All Models Datum Firewall bulkhead Leveling means Hatch sill on either side of fuselage Certification basis CAR 3, effective December 15, 1946, with no amendments, no exemptions. Type Certificate No. 787 issued June 13, 1947. Application for Type Certificate dated February 6, 1947 Bob Parker Mena, AR. ----- Original Message ----- From: "dddoyle" <[EMAIL PROTECTED]> To: "Coupers" <[EMAIL PROTECTED]> Sent: Tuesday, August 28, 2001 10:57 PM Subject: Re: [COUPERS] Fireproofing upholstery | ----[Please read http://ercoupers.com/disclaimer.htm before following any advice in this forum.]---- | | Bob, | | Would this apply to a 1965 Alon? Will I have to sue my future IA's to | convince them that there is a different qualification for CAR planes vs FAA | planes? | | Ken | | ----- Original Message ----- | From: rparker <[EMAIL PROTECTED]> | To: <[EMAIL PROTECTED]>; Coupers <[EMAIL PROTECTED]> | Sent: Tuesday, August 28, 2001 10:35 PM | Subject: Re: [COUPERS] Fireproofing upholstery | | | > ----[Please read http://ercoupers.com/disclaimer.htm before following any | advice in this forum.]---- | > | > Ken, | > Your material does not have to meet the burn test. If an aircraft is | > certified under FARs it must meet the burn test. You are certified under | > CARs and do not require a burn test. | > Certification basis | > Part 4a of the Civil Air Regulations | > Type Certificate No. 718 issued March 25, 1940 | > Application for Type Certificate dated April 20, 1938 | > Bob Parker | > Mena, AR. | > ----- Original Message ----- | > From: "dddoyle" <[EMAIL PROTECTED]> | > To: "Coupers" <[EMAIL PROTECTED]> | > Sent: Tuesday, August 28, 2001 8:33 PM | > Subject: RE: [COUPERS] Fireproofing upholstery | > | > | > | ----[Please read http://ercoupers.com/disclaimer.htm before following | any | > advice in this forum.]---- | > | | > | I'm planning to re-upholster my seats but the material I have selected | > does | > | not meet the FAA code for fireproofing. Does anyone on the net know | where | > | to get material treated to meet the FAA requirements? Thanks. | > | | > | | > | Ken Doyle | > | | > | | > | | > | | > | | > | | > | > | > | > | | | | | | ==^================================================================ EASY UNSUBSCRIBE click here: http://topica.com/u/?aVxiLm.aVzvvT Or send an email To: [EMAIL PROTECTED] This email was sent to: [EMAIL PROTECTED] T O P I C A -- Register now to manage your mail! http://www.topica.com/partner/tag02/register ==^================================================================
<<attachment: winmail.dat>>
