In final stages of building KIO2 interface .... Am doing Serial
Interface Test .... Using HyperTeminal, I am indeed able to issue the
suggested command, SH01; which causes a band increment.  However,
communication in the opposite direction is nonexistent; that is,
following the procedure on page 14 to issue the Test Message from the K2
causes no response on Hyperterminal. 

 

Any suggestions are, of course, deeply appreciated and welcome.


-------------------------------------------------------------------------------