I remember tailking to Chris about this some time ago.....I will see if I 
can get it to work, And let you know how it goes......I ordered the Mesa 
5i20 board a few moments ago....

On another note, I am seeing a few machines with tool changers showing 
up....Are you guys using classicladder to run the tool changer?

Dave

----- Original Message ----- 
From: "Chris Morley" <[EMAIL PROTECTED]>
To: "Enhanced Machine Controller (EMC)" <emc-users@lists.sourceforge.net>
Sent: Friday, April 25, 2008 10:49 AM
Subject: Re: [Emc-users] Classicladder


>
> Classicladder  version 7.124 is in CVS TRUNK and MODBUS should work as the 
> stand alone version except for there HAS to be a CONFIG file loaded with 
> the classicladder userspace program. The CONFIG file could be empty-it is 
> used to tell Classicladder to start MODBUS.
> eg.  loadusr -w classicladder --config=testmod example.clp
> I have not tested beyond seeing messages sent complaining about not 
> connecting (there was no hardware set up so was expecting this).
> I had no hardware available and now am very busy for a couple months away 
> at work.
> Whether Modbus support is enabled in EMC 2.3 is up to you/and or the lead 
> developers . If the lead developers don't want it enabled by default , 
> then I see no reason to not make it available by recompiling.
> If you do try the TRUNK version anytime soon please let me know how it 
> works
>
> I apoligize as this is the only docs I have made so far:
> http://wiki.linuxcnc.org/cgi-bin/emcinfo.pl?ClassicLadder_Ver_7.124
>
> cheers Chris Morley
>
> ________________________________
>> From: [EMAIL PROTECTED]
>> To: emc-users@lists.sourceforge.net
>> Date: Thu, 24 Apr 2008 21:17:16 -0400
>> Subject: [Emc-users] Classicladder
>>
>> Just to clarify, Has MODBUS been enabled in classicladder in the latest 
>> EMC release? If so, how exactly do you enable it? I understand how to 
>> enable it in TCP in but I haven't quite figured out the serial in the 
>> stand alone version.....Can some one point me to a reference for how to 
>> set up the config file, I thought it was supposed to be 9502 for the 
>> serial but this locks up classic ladder. Has anyone done this in either 
>> the stand alone version of classicladder or with EMC. I am using the 
>> latest versions of both. A documented example would help. I know the 
>> device I am using works because I use this with Mach 3 in windows with no 
>> issues.
>>
>>           Thanks in advance,
>>
>>                     Dave
>
> _________________________________________________________________
> Try Chicktionary, a game that tests how many words you can form from the 
> letters given. Find this and more puzzles at Live Search Games!
> http://g.msn.ca/ca55/207
> -------------------------------------------------------------------------
> This SF.net email is sponsored by the 2008 JavaOne(SM) Conference
> Don't miss this year's exciting event. There's still time to save $100.
> Use priority code J8TL2D2.
> http://ad.doubleclick.net/clk;198757673;13503038;p?http://java.sun.com/javaone
> _______________________________________________
> Emc-users mailing list
> Emc-users@lists.sourceforge.net
> https://lists.sourceforge.net/lists/listinfo/emc-users
> 


-------------------------------------------------------------------------
This SF.net email is sponsored by the 2008 JavaOne(SM) Conference 
Don't miss this year's exciting event. There's still time to save $100. 
Use priority code J8TL2D2. 
http://ad.doubleclick.net/clk;198757673;13503038;p?http://java.sun.com/javaone
_______________________________________________
Emc-users mailing list
Emc-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/emc-users

Reply via email to