Chris,
I have the baud rate set correctly......and the port.....what
about stop bits and parity for the serial port? I can change it in my device
but I am not sure what classic ladder is looking for......I have it hooked
up with some input bits being triggered and I get nothing from/to
classicladder.
----- Original Message -----
From: "Chris Morley" <[EMAIL PROTECTED]>
To: "Enhanced Machine Controller (EMC)" <[email protected]>
Sent: Friday, April 25, 2008 10:49 AM
Subject: Re: [Emc-users] Classicladder
>
> Classicladder version 7.124 is in CVS TRUNK and MODBUS should work as the
> stand alone version except for there HAS to be a CONFIG file loaded with
> the classicladder userspace program. The CONFIG file could be empty-it is
> used to tell Classicladder to start MODBUS.
> eg. loadusr -w classicladder --config=testmod example.clp
> I have not tested beyond seeing messages sent complaining about not
> connecting (there was no hardware set up so was expecting this).
> I had no hardware available and now am very busy for a couple months away
> at work.
> Whether Modbus support is enabled in EMC 2.3 is up to you/and or the lead
> developers . If the lead developers don't want it enabled by default ,
> then I see no reason to not make it available by recompiling.
> If you do try the TRUNK version anytime soon please let me know how it
> works
>
> I apoligize as this is the only docs I have made so far:
> http://wiki.linuxcnc.org/cgi-bin/emcinfo.pl?ClassicLadder_Ver_7.124
>
> cheers Chris Morley
>
> ________________________________
>> From: [EMAIL PROTECTED]
>> To: [email protected]
>> Date: Thu, 24 Apr 2008 21:17:16 -0400
>> Subject: [Emc-users] Classicladder
>>
>> Just to clarify, Has MODBUS been enabled in classicladder in the latest
>> EMC release? If so, how exactly do you enable it? I understand how to
>> enable it in TCP in but I haven't quite figured out the serial in the
>> stand alone version.....Can some one point me to a reference for how to
>> set up the config file, I thought it was supposed to be 9502 for the
>> serial but this locks up classic ladder. Has anyone done this in either
>> the stand alone version of classicladder or with EMC. I am using the
>> latest versions of both. A documented example would help. I know the
>> device I am using works because I use this with Mach 3 in windows with no
>> issues.
>>
>> Thanks in advance,
>>
>> Dave
>
> _________________________________________________________________
> Try Chicktionary, a game that tests how many words you can form from the
> letters given. Find this and more puzzles at Live Search Games!
> http://g.msn.ca/ca55/207
> -------------------------------------------------------------------------
> This SF.net email is sponsored by the 2008 JavaOne(SM) Conference
> Don't miss this year's exciting event. There's still time to save $100.
> Use priority code J8TL2D2.
> http://ad.doubleclick.net/clk;198757673;13503038;p?http://java.sun.com/javaone
> _______________________________________________
> Emc-users mailing list
> [email protected]
> https://lists.sourceforge.net/lists/listinfo/emc-users
>
-------------------------------------------------------------------------
This SF.net email is sponsored by the 2008 JavaOne(SM) Conference
Don't miss this year's exciting event. There's still time to save $100.
Use priority code J8TL2D2.
http://ad.doubleclick.net/clk;198757673;13503038;p?http://java.sun.com/javaone
_______________________________________________
Emc-users mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/emc-users